Data set 01
1950 Sylvania
Published operating points and test conditions from this source.
Rectifier
Other
DC output current capacitor-input
70 mA
CapacitorInputFilter
DC output current choke-input
70 mA
ChokeInputFilter
Rectifier - Full Wave ·Rectifier-Rectifier
Miniature full-wave vacuum rectifier for receiver and general electronic power supplies. Rated for approximately 1.25 kV peak inverse voltage, 70 mA DC output, and 245 mA peak current.
6X4 is a Rectifier vacuum tube documented in the RCA Receiving Tube Manual. The supplied excerpt was reviewed for heater data, section arrangement, maximum ratings, electrical characteristics, interelectrode capacitances, typical operating conditions, and stated applications.
Miniature 7-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
| Terminal | Section | Connection | Evidence |
|---|---|---|---|
| PIN1IS | A | IS — Internal Screen EIA chart transcription; manufacturer corroboration pending | Unverified EIA Base Connections, printed page 127, 5S |
| PIN2F | — | F — Filament EIA chart transcription; manufacturer corroboration pending | Unverified EIA Base Connections, printed page 127, 5S |
| PIN3P | A | P — Plate (Anode) EIA chart transcription; manufacturer corroboration pending | Unverified EIA Base Connections, printed page 127, 5S |
| PIN5G1 | A | G1 — Control Grid EIA chart transcription; manufacturer corroboration pending; preserve source designation G1 | Unverified EIA Base Connections, printed page 127, 5S |
| PIN7F | — | F — Filament EIA chart transcription; manufacturer corroboration pending | Unverified EIA Base Connections, printed page 127, 5S |
2 physical sections, each with unique specifications.
Section 1
Representative row for two identical rectifier sections; peak inverse, steady-state peak plate current and typical full-wave output values mapped from source.
Section 2
Second physical rectifier section; electrical properties populated from corresponding identical section.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
DC output current capacitor-input
70 mA
CapacitorInputFilter
DC output current choke-input
70 mA
ChokeInputFilter
Data set 02
Published operating points and test conditions from this source.
Heater Voltage
6.3 V
Heater Current
600 mA
Data set 03
Published operating points and test conditions from this source.
Maximum peak inverse voltage
1250 V
Nominal DC output current
70 mA
Maximum peak forward current
210 mA
Maximum RMS supply voltage
325 V
Forward voltage drop
22 V
Forward-voltage-drop test current
70 mA
Data set 04
Published operating points and test conditions from this source.
Peak Inverse Voltage
1250 V
Peak Anode Current
200 mA
RMS Input Voltage per Anode
450 V
Data set 05
Published operating points and test conditions from this source.
Heater/filament voltage
6.3 V
Published rating
Heater/filament current
600 mA
Published rating
AC supply voltage plate-to-plate
2x325 V RMS
FullWave
DC output current
70 mA
FullWave
Maximum capacitor-input filter capacitance
10 uF
CapacitorInputFilter
DC output voltage
310 V
FullWave
Data set 06
Published operating points and test conditions from this source.
Peak inverse plate voltage
1250 V
Steady-state peak plate current per plate
245 mA
Transient peak plate current per plate
1.1 A
Duration<=0.2s
DC output current
70 mA
DC output voltage
385 V
Iout=70mA
Data set 07
Published operating points and test conditions from this source.
Steady-state peak plate current per plate
245 mA
Transient peak plate current per plate
1.1 A
AC plate voltage per plate
325 V
CapacitorInputFilter
Input capacitor
10 uF
CapacitorInputFilter
DC output current
70 mA
CapacitorInputFilter
AC plate voltage per plate
400 V
ChokeInputFilter
Input choke
10 H
ChokeInputFilter
DC output current
70 mA
ChokeInputFilter
Tube voltage drop at 70 mA per plate
22 V
Data set 08
Published operating points and test conditions from this source.
AC Plate-Supply Voltage per Plate
450 V
ChokeInputFilter
AC Plate-Supply Voltage per Plate
325 V
CapacitorInputFilter
DC Output Voltage at Filter Input
340 V
ChokeInputFilter;Iout=70mA
DC Output Voltage at Filter Input
310 V
CapacitorInputFilter;Iout=70mA
Data set 09
Published operating points and test conditions from this source.
Heater voltage
6.3 V
Heater current
600 mA
Peak inverse voltage
1250 V
FullWave
DC output current
70 mA
FullWave
Peak plate current per plate
245 mA
EachPlate
Maximum heater-cathode voltage
450 V
AC plate voltage per plate
325 V
CapacitorInputFilter
Forward voltage drop
22 V
Data set 10
Published operating points and test conditions from this source.
volte
4 V
Characteristic;PublishedValue1
volte
3 V
Characteristic;PublishedValue2
volte
6 V
Characteristic;PublishedValue3
missible heater-voltage range is from
6 V
Characteristic;PublishedValue1
missible heater-voltage range is from
8 V
Characteristic;PublishedValue2
Peak Inverse Plate Voltage
1250 V
MaximumRating
Steady-State Peak Plate Current (Per Plate)
245 mA
MaximumRating
DC Output Voltage (At filter input)t
360 V
MaximumRating
Average Output Current (Each plate)t
45 mA
MaximumRating
cycle
75 %
MaximumRating
per plate of
1.1 A
MaximumRating
Ef=
6 V
TypicalOperation;PublishedValue1
Ef=
6.3 V
TypicalOperation;PublishedValue2
Ef=
60 V
TypicalOperation;PublishedValue3
„„ .„ (
520 ohm
TypicalOperation
PER PLATE ^
400 ohm
TypicalOperation;PublishedValue1
PER PLATE ^
6 ohm
TypicalOperation;PublishedValue2
PER PLATE ^
-8 ohm
TypicalOperation;PublishedValue3
Effective Plate Supply Impedance (Each plate)
525 ohm
TypicalOperation
< „. II
6.3 V
TypicalOperation
Peak Inverse Plate Voltage
1250 V
Section1
Nominal Output Current
70 mA
Section1
Peak Forward Current
245 mA
Section1
Maximum Heater-Cathode Voltage
450 V
Section1