Skip to main content

Rectifier - TV Line Scan Boost ·Rectifier

6S2

Indirectly heated high-voltage half-wave rectifier explicitly designed for television EHT supplies driven from line-timebase flyback pulses, converting horizontal-scan energy into the CRT accelerating-voltage supply.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
B9A
Socket code
B9A
Base pins
9
Nominal heater
6.3 V / 90 mA

Description

Indirectly heated high-voltage half-wave rectifier for television EHT supplies driven from line-timebase flyback pulses.

Socket description

Small-button Noval 9-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
B9A
Socket code
B9A
Base pins
9
Nominal heater voltage
6.3 V
Nominal heater current
90 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

B9A - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Rectifier peak inverse voltage
24000 V
Rectifier nominal output current
3 mA
Rectifier peak forward current
40 mA

Published Rogers/JETEC/RMA ratings and characteristics promoted where applicable; additional data retained as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1959 Rogers

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Application

  • Application

    Television EHT rectifier

Data set 02

1961 Ferranti Technical Handbook

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Peak inverse voltage

    22 kV

    PulseInput

  • Rectified current maximum

    800 uA

    PulseInput

  • Peak plate current maximum

    40 mA

    PulseInput

  • Reservoir capacitance maximum

    2000 pF

    PulseInput

  • RMS input voltage maximum

    5 kV

    SinusoidalInput

  • Rectified current maximum

    3 mA

    SinusoidalInput

  • Reservoir capacitance maximum

    0.2 uF

    SinusoidalInput

  • Minimum limiting resistance

    100 kOhm

    SinusoidalInput

  • X-ray shielding threshold

    6 kV

    ShieldingMayBeRequiredAboveThisPlateVoltage

Capacitance

  • Plate-to-heater/cathode/shield capacitance

    1.8 pF