Skip to main content

Specialized - Radiation Counter ·FissionIonizationDetector

6376A

Dual-range thermal-neutron detector designed to operate either as a fission counter or as an ionization chamber. This dual operating mode permits neutron measurements over a wider useful flux range than a single-mode detector.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

Dual-range thermal-neutron detector usable as either a fission counter or ionization chamber.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

FissionIonizationDetector

X-ray radiationInterelectrode capacitances
Max plate voltage
300 V

Published electrical limits and characteristics promoted from the approved source. Values without an applicable promoted column are retained in TUBE_SECTION_PARAMETER.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1947 Westinghouse

Published operating points and test conditions from this source.

SECTION 1

FissionIonizationDetector

Other

  • MaximumPlateOrOperatingVoltage

    300 V

  • TypicalCounterOperatingVoltage

    300 V

  • TotalIntegratedNeutronFluxMaximum

    200000000000000000 n/cm2

Characteristic

  • CounterNeutronSensitivity

    0.7 count/n/cm2

  • IonizationChamberNeutronSensitivity

    1.4e-12 A/(n/cm2/s)