Data set 01
1965 Sylvania Electronic Tubes Vol3
Published operating points and test conditions from this source.
Cathode Ray
Characteristics
Heater Voltage
6.3 V
Heater Current
300 mA
Nominal; ±10%
Focusing Method
Electrostatic text
Deflection Method
Magnetic text
Horizontal Deflection Angle
52 deg
Vertical Deflection Angle
27 deg
Diagonal Deflection Angle
54 deg
Fluorescence
Orange text
Persistence
Very Long text
Grid1-to-All Capacitance
12 pF
Approximate
Cathode-to-All Capacitance
9.5 pF
Approximate
Phosphorescence
Orange text
Other
Maximum Anode Voltage
4500 V
Maximum Anode Input
6 W
Focus Electrode Voltage Minimum
-500 V
Grid4
Focus Electrode Voltage Maximum
1100 V
Grid4
Maximum Grid2 Voltage
550 V
Maximum Grid1 Negative Bias
165 V
Maximum Grid1 Positive Peak
2 V
Maximum Heater-Cathode Voltage
180 V
EitherPolarity
Maximum Altitude
70000 ft
Operating Temperature Minimum
-55 degC
Operating Temperature Maximum
85 degC
Anode Voltage
4000 V
Focus Voltage Minimum
0 V
Grid4
Focus Voltage Maximum
120 V
Grid4
Grid2 Voltage
300 V
Grid1 Cutoff Voltage Minimum
-45 V
Grid1 Cutoff Voltage Maximum
-15 V
Maximum Modulation Voltage
15 V
Maximum Line Width
0.006 in
BeamCurrent=10uA