Data set 01
1938 Raytheon
Published operating points and test conditions from this source.
Cathode Ray
Application
Application
Oscilloscope_Display text
Specialized - Cathode Ray ·CathodeRay
Five-inch flat optical-glass CRT for high-resolution photographic and oscillographic recording, with electrostatic focusing, magnetic deflection, and P11 screen. Published anode capability reaches approximately 22 kV.
Five-inch flat optical-glass CRT for high-resolution photographic/oscillographic recording, with electrostatic focus and magnetic deflection.
Small-shell Duodecal 6-contact CRT base
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Cathode-ray display/scanning system; published focusing, deflection and high-voltage data retained as parameters.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Application
Oscilloscope_Display text
Data set 02
Published operating points and test conditions from this source.
Heater Voltage
6.3 V
Nominal
Heater Current
600 mA
Nominal
Data set 03
Published operating points and test conditions from this source.
Grid No. 1 to all other electrodes capacitance
9 pF
Grid No. 2 to all other electrodes capacitance
7 pF
Cathode to all other electrodes capacitance
7 pF
Maximum anode voltage
22000 V
Maximum grid No. 3 focus voltage
5000 V
Maximum grid No. 2 voltage
600 V
Maximum negative grid No. 1 bias magnitude
180 V
Peak heater-cathode voltage during warm-up
450 V
Peak heater-cathode voltage after warm-up
180 V
Typical anode voltage low-voltage condition
10000 V
Typical anode voltage high-voltage condition
20000 V
Typical focus voltage range at 10 kV
2070 to 2370 V
Typical focus voltage range at 20 kV
4140 to 4740 V
Typical grid No. 2 voltage
300 V
Grid No. 1 cutoff voltage range
-65 to -40 V
Typical line width
0.0015 in
Grid No. 1 circuit resistance maximum
1.5 MOhm