Data set 01
1965 Sylvania Electronic Tubes Vol3
Published operating points and test conditions from this source.
Cathode Ray
Characteristics
Focusing method
Electrostatic
Deflection method
Electrostatic
Heater voltage
6.3 V
Heater current
600 mA
Fluorescence
Blue
Persistence
Short
Deflection-factor uniformity maximum
1 %
Line width maximum
0.032 in
Useful scan minimum
4 x 2.5 in
Trace-angle tolerance
+/-0.8 deg
Pattern distortion at 100% useful scan maximum
2 %
Construction
Phosphor
P11
Application
Application
Oscilloscope / instrument / special-purpose display
Other
Anode-2 voltage maximum
6600 V
Anode-1 focus voltage maximum
1650 V
Typical anode-2 voltage
2500 V
Typical focus voltage range
0 to 300 V
Grid-1 circuit resistance maximum
1.5 Mohm
Deflection-circuit resistance maximum
1 Mohm
Anode-2 input maximum
6 W