Data set 01
1938 Raytheon
Published operating points and test conditions from this source.
Cathode Ray
Application
Application
Oscilloscope_Display text
Specialized - Cathode Ray ·CathodeRay
Five-inch P1 electrostatic cathode-ray tube for oscillograph and precision-instrument display, with manufacturer-defined accelerating, focusing, and deflection characteristics.
5-inch electrostatic-focus and electrostatic-deflection cathode-ray tube designed for high deflection sensitivity and oscillographic display.
Medium-shell Diheptal 12-contact CRT base
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Cathode-ray display/scanning system; published focusing, deflection and high-voltage data retained as parameters.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Application
Oscilloscope_Display text
Data set 02
Published operating points and test conditions from this source.
Heater Voltage 6.3 Volts
6.3 V
Heater Voltage 6.3 Volts
Anode No. 2 Voltage! 6600 Volts dc
6600 V
Anode No. 2 Voltage! 6600 Volts dc
Anode No. 1 Voltage (Focusmg Electrode) 1650 Volts dc
1650 V
Anode No. 1 Voltage (Focusmg Electrode) 1650 Volts dc
Grid No. 1 Voltage
1 V
Grid No. 1 Voltage
Any Deflection Plate 1320 Volts
1320 V
Any Deflection Plate 1320 Volts
Anode No. 2 Voltage . 2500 Volts dc
2500 V
Anode No. 2 Voltage . 2500 Volts dc
Anode No. 1 Voltage for Focus . 0to 300 Volts dc
300 V
Anode No. 1 Voltage for Focus . 0to 300 Volts dc
Grid No. 1 Voltage Required for Cutoff2 —34t0-56 Volts dc
-56 V
Grid No. 1 Voltage Required for Cutoff2 —34t0-56 Volts dc
1. The product of the Anode No. 2 Voltage and Average Anode No. 2 Current should be limited to 6 wat
6 W
1. The product of the Anode No. 2 Voltage and Average Anode No. 2 Current should be limited to 6 watts.
Data set 03
Published operating points and test conditions from this source.
Focusing method
1 code
Electrostatic
Deflection method
1 code
Electrostatic
Deflection factor D1-D2
-
Published range 40 to 50 V/in
Deflection factor D3-D4
-
Published range 20 to 25 V/in
Minimum useful screen
41 in
Accelerator voltage maximum
6000 V
Accelerator voltage
2500 V
Grid No. 1 voltage
-
Published range -56 to -34 V
Grid No. 1 negative bias maximum
200 V
Cathode to all other electrodes
2.7 pF
Approximate or first published bound
Grid No. 1 to all other electrodes
2.9 pF
Approximate or first published bound
Data set 04
Published operating points and test conditions from this source.
Focusing method
Electrostatic
Deflection method
Electrostatic
Heater voltage
6.3 V
Heater current
600 mA
Fluorescence
Green
Persistence
Medium
Deflection-factor uniformity maximum
1 %
Line width maximum
0.032 in
Useful scan minimum
4 x 2.5 in
Phosphor
P1
Application
Oscilloscope / instrument / special-purpose display
Anode-2 voltage maximum
6600 V
Anode-1 focus voltage maximum
1650 V
Typical anode-2 voltage
2500 V
Typical focus voltage range
0 to 300 V
Grid-1 circuit resistance maximum
1.5 Mohm
Deflection-circuit resistance maximum
1 Mohm
Anode-2 input maximum
6 W