Skip to main content

Specialized - Cathode Ray ·CathodeRay

5ADP1

Flat-face five-inch high-sensitivity cathode-ray tube with electrostatic focusing and electrostatic deflection, designed for precision oscillographic applications. Its P1 screen supports accurate direct waveform viewing.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
DUODECAL11
Base pins
12
Nominal heater
6.3 V / 600 mA

Description

Flat-face 5-inch high-sensitivity electrostatic-focus and electrostatic-deflection cathode-ray tube for precision oscillographic applications.

Socket description

Duodecal 11-contact CRT base

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
DUODECAL11
Base pins
12
Nominal heater voltage
6.3 V
Nominal heater current
600 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Cathode Ray

X-ray radiationInterelectrode capacitances
Max plate voltage
16 V

CRT-specific electrode voltages, deflection factors, capacitances, focus/cutoff data, and other published electrical values are stored as section parameters because the promoted section columns are primarily conventional valve fields.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1938 Raytheon

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Application

  • Application

    Oscilloscope_Display text

Data set 02

1950 Sylvania

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristic

  • 5sADP1A 5ADP2A 5ADP7A 5ADP11A 5ADP31A Electrostatic Deflection

    31 A

    5sADP1A 5ADP2A 5ADP7A 5ADP11A 5ADP31A Electrostatic Deflection

  • Heater Voltage . . . . . . . . .« « o v o oo 6.3 Volts

    6.3 V

    Heater Voltage . . . . . . . . .« « o v o oo 6.3 Volts

  • Minimum Anode No. 3 Voltage (SADP-,5ADP-B) . . . . . . . .. .. ... ... 1500 Volts dc

    1500 V

    Minimum Anode No. 3 Voltage (SADP-,5ADP-B) . . . . . . . .. .. ... ... 1500 Volts dc

  • Minimum Anode No. 3 Voltage (SADP-A) . . . . . . . . . . .. ... ..... 2500 Volts dc

    2500 V

    Minimum Anode No. 3 Voltage (SADP-A) . . . . . . . . . . .. ... ..... 2500 Volts dc

  • Anode No. 2 Voltage? . . . . . . . . . . o 0o e e 2860 Volts dc

    2860 V

    Anode No. 2 Voltage? . . . . . . . . . . o 0o e e 2860 Volts dc

  • AnodeNo.1Voltage . . . . . . . . . . . . e 1100 Volts dc

    1100 V

    AnodeNo.1Voltage . . . . . . . . . . . . e 1100 Volts dc

  • Grid No. 1 Voltage

    1 V

    Grid No. 1 Voltage

  • Peak Voltage Between Anode No. 2 and Any Deflection Plate . . . . . . . . . . . . 550 Volts

    550 V

    Peak Voltage Between Anode No. 2 and Any Deflection Plate . . . . . . . . . . . . 550 Volts

  • AnodeNo.3Voltage . . . . . . . . . . . . . .. e e 3000 Volts dc

    3000 V

    AnodeNo.3Voltage . . . . . . . . . . . . . .. e e 3000 Volts dc

  • AnodeNo.2Voltage . . . . . . . . . .. ... o 1500 Volts dc

    1500 V

    AnodeNo.2Voltage . . . . . . . . . .. ... o 1500 Volts dc

  • Anode No. 1 Voltage for Focus . . . . . . . . . . . . . ... .. .. ... 300 to 515 Volts dc

    515 V

    Anode No. 1 Voltage for Focus . . . . . . . . . . . . . ... .. .. ... 300 to 515 Volts dc

  • Grid No. 1 Voltage Required for Cutoff3 . . . . . . . . . . ... . ... .. —34 to —56 Volts dc

    56 V

    Grid No. 1 Voltage Required for Cutoff3 . . . . . . . . . . ... . ... .. —34 to —56 Volts dc

  • . The product of the Anode No. 2 Voltage and the Average Anode No. 2 Current should be limited to 6

    6 W

    . The product of the Anode No. 2 Voltage and the Average Anode No. 2 Current should be limited to 6 watts.

Other

  • Maximum Anode No. 3 Voltage . . . . . . . . . . . . . . ... ... ..... 6600 Volts dc

    6600 V

    Maximum Anode No. 3 Voltage . . . . . . . . . . . . . . ... ... ..... 6600 Volts dc

  • Radio of Anode No. 3 Voltage to Anode No. 2 Voltage . . . . . . . . . .. . ... 2.3:1 Max.

    2 V

    Radio of Anode No. 3 Voltage to Anode No. 2 Voltage . . . . . . . . . .. . ... 2.3:1 Max.

  • range if this tube is operated at higher than the manufacturer's Maximum Rated Anode Voltage or 16,0

    16 V

    range if this tube is operated at higher than the manufacturer's Maximum Rated Anode Voltage or 16,000 volts, whichever is less.

Data set 03

1958 Compagnie General

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristics

  • Screen Diameter

    13 cm

  • Focusing Method

    Electrostatic text

  • Deflection Method

    Electrostatic text

  • Post-Acceleration Electrode

    Present text

Data set 04

1960 Du Mont

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristics

  • Focusing method

    1 code

    Electrostatic

  • Deflection method

    1 code

    Electrostatic

  • Deflection factor D1-D2

    -

    Published range 40 to 50 V/in

  • Deflection factor D3-D4

    -

    Published range 30.5 to 37.5 V/in

Other

  • Accelerator voltage maximum

    3000 V

  • Accelerator voltage

    1500 V

  • Post-accelerator voltage maximum

    6000 V

  • Post-accelerator voltage

    3000 V

  • Grid No. 1 voltage

    -

    Published range -56 to -34 V

  • Grid No. 1 negative bias maximum

    200 V

Capacitance

  • Cathode to all other electrodes

    3.1 pF

    Approximate or first published bound

  • Grid No. 1 to all other electrodes

    4.2 pF

    Approximate or first published bound

Data set 05

1965 Sylvania Electronic Tubes Vol3

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristics

  • Heater Voltage

    6.3 V

  • Heater Current

    600 mA

    Nominal; ±10%

  • Focusing Method

    Electrostatic text

  • Deflection Method

    Electrostatic text

  • Fluorescence

    Green text

  • Persistence

    Medium text

  • Cathode-to-All Capacitance Minimum

    3.1 pF

  • Cathode-to-All Capacitance Maximum

    5.8 pF

  • Grid1-to-All Capacitance Minimum

    4.2 pF

  • Grid1-to-All Capacitance Maximum

    7.9 pF

Other

  • Maximum Anode3 Voltage

    6600 V

  • Minimum Anode3 Voltage

    1500 V

    5ADP-B or standard family

  • Maximum Anode2 Voltage

    2860 V

  • Maximum Anode1 Voltage

    1100 V

  • Maximum Grid1 Negative Bias

    200 V

  • Maximum Grid1 Positive Peak

    2 V

  • Maximum Heater-Cathode Voltage

    180 V

    EitherPolarity

  • Maximum Anode2-to-Deflection-Plate Voltage

    550 V

  • Typical Anode3 Voltage

    3000 V

  • Typical Anode2 Voltage

    1500 V

  • Focus Voltage Minimum

    300 V

    Anode1

  • Focus Voltage Maximum

    515 V

    Anode1

  • Grid1 Cutoff Voltage Minimum

    -56 V

  • Grid1 Cutoff Voltage Maximum

    -34 V

  • Deflection Factor Plates 1-2 Minimum

    40 V/in

  • Deflection Factor Plates 1-2 Maximum

    50 V/in

  • Deflection Factor Plates 3-4 Minimum

    30.5 V/in

  • Deflection Factor Plates 3-4 Maximum

    37.5 V/in

  • Maximum Modulation Voltage

    45 V

  • Maximum Line Width

    0.03 in

  • Maximum Grid1 Circuit Resistance

    1.5 Mohm

  • Maximum Deflection Plate Circuit Resistance

    5 Mohm

Data set 06

1971 RCA HB3 Binder 1 of 7

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristics

  • Voltage

    6.3 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • Current — published value 1

    0.6

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • Current — published value 2

    10

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • Grid No.l to all other electrodes — published value 1

    4.2

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • Grid No.l to all other electrodes — published value 2

    7.9

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • Pin 1 -Heater — published value 1

    1

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • Pin 1 -Heater — published value 2

    9

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • Pin 2 -Cathode

    2

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • Pin 3 -Grid No.1

    3

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • Pin 5 -Grid No.3 — published value 1

    5

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • Pin 5 -Grid No.3 — published value 2

    11

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • Electrode

    14

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • With any Bost-ultor voltage (Ec51 between 2oao` and 600o volts — published value 1

    2 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • With any Bost-ultor voltage (Ec51 between 2oao` and 600o volts — published value 2

    600 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • for. Focus — published value 1

    20 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • for. Focus — published value 2

    34.5 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • Spot — published value 1

    2.25 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • Spot — published value 2

    3.75 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • Spot Position

    4

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • ~~ 0.t or near this rat ing ,, the effective resistance of the ul for supply

    0

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • should be adequate to limit the ultor input power to 6 watts

    6 W

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • ~ It is recommended that the post—ultor voltage be not lessthan 3000

    3000 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • ## with neater voltage of 6.3

    6.3 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • allot voltage of 2000 volts, grid—No.3 voltage adjusted to give focus,`

    2000 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • u ndeflec led, focused spot will fall within a circle having an 8—mm

    8

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • and ultor voltage of — published value 1

    1 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • and ultor voltage of — published value 2

    0 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • and ultor voltage of — published value 3

    2000 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • Focus — published value 1

    300 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • Focus — published value 2

    515 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

Other

  • POST—ULTOR VOLTAGE

    6000 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • ULTOR VOLTAGE

    2600 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • ULTOR VOLTAGE — published value 1

    2 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • ULTOR VOLTAGE — published value 2

    3.1 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.

  • GRID—No.3 VOLTAGE

    1000 V

    Published CRT datasheet value; where a source row has several numbers they represent its separate limits or operating conditions.