Skip to main content

Specialized - Radiation Counter ·GeigerMullerCounter

5944

Permanent-sensitivity beta-gamma Geiger-Müller counter using halogen-quenched neon gas. Stable self-quenching pulse operation suits general-purpose beta and gamma survey, monitoring, and measurement equipment.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

The Amperex 5944 is a permanent-sensitivity beta-gamma counter tube using a neon-plus-halogen gas filling for radiation survey and monitoring service. The source specifies plateau, starting-voltage, counting-rate, background, and life data.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

GeigerMullerCounter

X-ray radiationInterelectrode capacitances
Regulator starting voltage
825 V

Gas-filled Geiger counter section; counter performance preserved as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1953 Amperex

Published operating points and test conditions from this source.

SECTION 1

GeigerMullerCounter

Other

  • Operating voltage

    900 V

    Published source value

  • Starting voltage

    - to 825 V

    Published source value

Capacitance

  • Terminal capacitance

    2.4 pF

    Published source value

Characteristic

  • Maximum counting rate

    1700 counts/s

    Published source value

  • Dead time, approximate

    100 us

    Published source value