Skip to main content

Power - Tetrode (NOT beam) (over 1000V 100W) ·Tetrode

4CX35000C

Special 4CX35000 variant designed particularly for plate-and-screen-modulated Class-C RF amplification at very high power, with full transmitting ratings extending to about 110 MHz.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
10 V / 300 A

Description

Forced-air-cooled coaxial metal-ceramic RF power tetrode for high-power amplifier service.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
10 V
Nominal heater current
300 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Tetrode

X-ray radiationInterelectrode capacitances
Amplification factor
5.5
Max plate voltage
20000 V
Max screen voltage
2500 V
Max plate dissipation
35000 W
Max screen dissipation
1750 W
Max grid dissipation
500 W
Max cathode current
16 A

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1965 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Tetrode

Characteristic

  • Heater/Filament Voltage

    10 V

  • Heater/Filament Current

    300 A

  • Amplification Factor

    5.5

Other

  • Maximum DC Plate Voltage

    10000 V

  • Maximum DC Screen Voltage

    2500 V

  • Maximum Plate/Cathode Current

    10 A

  • Maximum Plate Dissipation

    35000 W

  • Maximum Screen Dissipation

    1500 W

  • Maximum Grid Dissipation

    450 W

  • Frequency for Maximum Ratings

    110 MHz

  • Typical Plate Output Power

    55.6 W

Construction

  • Cooling

    Forced air

Data set 02

1971 English Electric Valve

Published operating points and test conditions from this source.

SECTION 1

Tetrode

Other

  • Filament voltage

    10 V

  • Filament current

    300 A

  • Frequency for full ratings

    30 MHz

  • Output power, class C telegraphy

    82.5 kW