Data set 01
1962 Eimac
Published operating points and test conditions from this source.
Tetrode
Other
for use at the fifty kilowatt output power level, The
5000 kilowatt
for use at the fifty kilowatt output power level, The 4CX35,000A is recommended
Class-AB] push-pull a-f amplifier or modulator. The
5000 a
Class-AB] push-pull a-f amplifier or modulator. The 4CX35,000C is a special version
Voltage
10 Volts
Voltage - - - - - - 10.0 Volts
Current
300 Amperes
Current - - - - - - 300 Amperes
Feedback
2.3 uuf
Feedback - - - 2,3 2.3 uuf
Frequency for Maximum Ratings
110 Megacycles
Frequency for Maximum Ratings - - - - 110 Megacycles
Maximum Seal Temperature
250 °C
Maximum Seal Temperature - - - 250°C
Maximum Anode Core Temperature
250 °C
Maximum Anode Core Temperature - - - - 250°C
D-C PLATE VOLTAGE
10000 VOLTS
D-C PLATE VOLTAGE - - - - - 10,000 VOLTS
D-C SCREEN VOLTAGE
2500 VOLTS
D-C SCREEN VOLTAGE - - - - - 2500 VOLTS
D-C PLATE CURRENT
10 AMPERES
D-C PLATE CURRENT - - - - - 10.0 AMPERES
PLATE DISSIPATION
35000 WATTS
PLATE DISSIPATION - - - - - 35,000 WATTS
SCREEN DISSIPATION
1500 WATTS
SCREEN DISSIPATION - - - - - 1500 WATTS
GRID DISSIPATION
450 WATTS
GRID DISSIPATION - - - - - 450 WATTS
D-C Plate Voltage
10000 Volts
D-C Plate Voltage - - - - - 10,000 Volts
D-C Screen Voltage
750 Volts
D-C Screen Voltage - - - - - 750 Volts
D-C Grid Voltage
425 Volts
D-C Grid Voltage - - - - - -425 Volts
D-C Plate Current
6.8 Amperes
D-C Plate Current - - - - - 6.80 Amperes
D-C Screen Current
925 Ma
D-C Screen Current - - - - - 925 Ma
D-C Grid Current
320 Ma
D-C Grid Current - - - - - 320 Ma
Peak R-F Grid Voltage
575 Volts
Peak R-F Grid Voltage - - - - - 575 Volts
Driving Power
185 Watts
Driving Power - - - - - 185 Watts
Plate Dissipation
11700 Watts
Plate Dissipation - - - - - 11,700 Watts
Plate Output Power
56500 Watts
Plate Output Power - - - - - 56,500 Watts
D-C PLATE VOLTAGE
10000 VOLTS
D-C PLATE VOLTAGE - - - . 10,000 VOLTS
D-C SCREEN VOLTAGE
1250 VOLTS
D-C SCREEN VOLTAGE - - - - - 1250 VOLTS
D-C PLATE CURRENT
10 AMPERES
D-C PLATE CURRENT - - - - - 10.0 AMPERES
PLATE DISSIPATION
23500 WATTS
PLATE DISSIPATION - - - - - 23,500 WATTS
SCREEN DISSIPATION
1500 WATTS
SCREEN DISSIPATION - - - - - 1500 WATTS
GRID DISSIPATION
450 WATTS
GRID DISSIPATION - - - - - 450 WATTS
D-C Plate Voltage
10000 Volts
D-C Plate Voltage - - - - - 10,000 Volts
D-C Screen Voltage
750 Volts
D-C Screen Voltage - - - - - 750 Volts
Peak A-F Screen Voltage (for
705 A
Peak A-F Screen Voltage (for 100-percent modulation)* - 705 Volts
D-C Grid Voltage
525 Volts
D-C Grid Voltage - - - - - -525 Volts
D-C Plate Current
6.7 Amperes
D-C Plate Current - - - - - 6.70 Amperes
D-C Screen Current
1.05 Amperes
D-C Screen Current - - - - - 1.05 Amperes
D-C Grid Current
315 Ma
D-C Grid Current - - - - - 315 Ma
Peak R-F Grid Voltage
680 Volts
Peak R-F Grid Voltage - - - - - 680 Volts
Driving Power
215 Watts
Driving Power - - - - - 215 Watts
Plate Dissipation (at
17100 Watts
Plate Dissipation (at 100% Modulation)* - - - 17,100 Watts
Plate Output Power
55600 Watts
Plate Output Power - - - - - 55,600 Watts
D-C PLATE VOLTAGE
10000 VOLTS
D-C PLATE VOLTAGE - - - - - 10,000 VOLTS
D-C SCREEN VOLTAGE
2500 VOLTS
D-C SCREEN VOLTAGE - - - - - 2500 VOLTS
D-C PLATE CURRENT
10 AMPERES
D-C PLATE CURRENT - - - - - 10.0 AMPERES
PLATE DISSIPATION
35000 WATTS
PLATE DISSIPATION - - - - - 35,000 WATTS
SCREEN DISSIPATION
1500 WATTS
SCREEN DISSIPATION - - - - - 1500 WATTS
GRID DISSIPATION
450 WATTS
GRID DISSIPATION - - - - - 450 WATTS
D-C Plate Voltage
10000 Volts
D-C Plate Voltage - - - - - 10,000 Volts
D-C Screen Voltage
1500 Volts
D-C Screen Voltage - - - - - 1500 Volts
D-C Grid Voltage *
290 Volts
D-C Grid Voltage * - - - - - -290 Volts
Zero-Sig D-C Plate Current
2 Amperes
Zero-Sig D-C Plate Current - - - - 2.00 Amperes
Max-Sig D-C Plate Current
8.75 Amperes
Max-Sig D-C Plate Current - - - - 8.75 Amperes
Max-Sig D-C Screen Current
270 Ma
Max-Sig D-C Screen Current - - - - 270 Ma
Peak R-F Grid Voltage
265 Volts
Peak R-F Grid Voltage - - - - - 265 Volts
Driving Power
0 Watts
Driving Power - - - - - 0 Watts
Plate Dissipation
32500 Watts
Plate Dissipation - - - - - 32,500 Watts
Max-Sig Plate Output Power
55000 Watts
Max-Sig Plate Output Power .- - - - 55,000 Watts
Resonant Load Impedance
590 Ohms
Resonant Load Impedance - - - - - 590 Ohms
D-C PLATE VOLTAGE
10000 VOLTS
D-C PLATE VOLTAGE - - - - - 10,000 VOLTS
D-C SCREEN VOLTAGE
2500 VOLTS
D-C SCREEN VOLTAGE - - - - - 2500 VOLTS
D-C PLATE CURRENT
10 AMPERES
D-C PLATE CURRENT - - - - - 10.0 AMPERES
PLATE DISSIPATION
35000 WATTS
PLATE DISSIPATION - - - - - 35,000 WATTS
SCREEN DISSIPATION
1500 WATTS
SCREEN DISSIPATION - - - - - 1500 WATTS
GRID DISSIPATION
450 WATTS
GRID DISSIPATION - - - - - 450 WATTS
D-C Plate Voltage - - - Co
10000 Volts
D-C Plate Voltage - - - Co- - 10,000 Volts
D-C Screen Voltage
1500 Volts
D-C Screen Voltage - - - - 1500 Volts
D-C Grid Voltage *
290 Volts
D-C Grid Voltage * - - - - -290 Volts
Zero-Sig D-C Plate Current
4 Amperes
Zero-Sig D-C Plate Current - - - 4.00 Amperes
Max-Sig D-C Plate Current
17.5 Amperes
Max-Sig D-C Plate Current - - - - 17.5 Amperes
Max-Sig D-C Screen Current
540 Ma
. Max-Sig D-C Screen Current - - - - 540 Ma
Peak A-F Driving Voltage (Per Tube)
265 A
Peak A-F Driving Voltage (Per Tube) - - - 265 Volts
Driving Power
0 Watts
Driving Power - - - - - 0 Watts
Load Resistance, Plate-to-Plate
1180 Ohms
Load Resistance, Plate-to-Plate - - 1180 Ohms
Plate Dissipation (Per Tube)
32500 Watts
Plate Dissipation (Per Tube) - - - 32,500 Watts
Max-Sig Plate OQutput Power
110000 Watts
Max-Sig Plate OQutput Power - - - 110,000 Watts
and the
250 °C
and the 4CX35,000C is 250°C, Sufficient forced-air cooling must be provided to
seals below
250 °C
seals below 250°C. Tube life is usually prolonged if these areas are maintained
maintain anode-core and seal temperatures below
225 °C
maintain anode-core and seal temperatures below 225°C with an inlet-air temper-
ature of
30 °C
ature of 50°C are tabulated below for operation below 30 Mc. These data are for
*% Since the power dissipated by the filament represents about
3000 watts
*% Since the power dissipated by the filament represents about 3000 watts and since
watts, allowance has been made in preparing this tabulation for an additional
5000 watts
watts, allowance has been made in preparing this tabulation for an additional 5000