Skip to main content

Power - Tetrode (NOT beam) (over 1000V 100W) ·Tetrode

4CV250000

High-power ceramic/metal transmitting tetrode designed for RF power amplification, linear amplification, oscillation, modulation, broadcast, or related high-power service.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
12 V / 660 A

Description

The EIMAC 4CV250,000 is a ceramic-metal vapor-cooled power tetrode intended for the 250 to 500 kilowatt output level and high-power amplifier or modulator service.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
12 V
Nominal heater current
660 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Tetrode

X-ray radiationInterelectrode capacitances
Amplification factor
4.5
Max plate voltage
25000 V
Max screen voltage
2500 V
Max plate dissipation
250000 W
Max screen dissipation
3500 W
Max grid dissipation
1500 W
Max cathode current
50 A

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 Eimac

Published operating points and test conditions from this source.

SECTION 1

Tetrode

Capacitance

  • Input Capacitance

    875 pF

    Grounded cathode

  • Output Capacitance

    115 pF

    Grounded cathode

  • Feedback Capacitance

    1.2 pF

    Grounded cathode

Data set 02

1965 Eimac Tube Manual

Published operating points and test conditions from this source.

SECTION 1

Tetrode

Characteristic

  • Heater/Filament Voltage

    12 V

Other

  • Maximum DC Plate Voltage

    25000 V

  • Maximum DC Screen Voltage

    2500 V

  • Maximum Plate/Cathode Current

    50 A

  • Maximum Plate Dissipation

    250000 W

  • Maximum Screen Dissipation

    3500 W

  • Maximum Grid Dissipation

    1500 W

  • Frequency for Maximum Ratings

    30 MHz

Construction

  • Cooling

    Vapor and forced air

Application

  • Intended Output Power Range

    250-500 kW