Exact variations of 4BZ6
These designations belong to the same electrical variation group. Their names may differ because of international standards, manufacturing tolerances, or materials, but they are recorded as electrically equivalent—not merely substitutes.
4JH6 Voltage Pentode - Remote Cutoff (single)
- Base
- 7CM
- Socket
- B7G
- Base pins
- 7
- Sections
- 1
- Heater voltage
- 4.2 V
- Heater current
- 0.45 A
Replacement tubes for 4BZ6
The following tubes are recorded as possible replacements for 4BZ6. This direction does not establish that 4BZ6 can replace them.
Voltage Pentode - Sharp Cutoff (single)
The database records 4AU6 as a possible replacement for4BZ6.
- Not suitable for all circuits
| Specification | Original tube | Replacement |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Sharp Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | 7CM | 7BK |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 4.2 V | 4.2 V |
| Heater current | 0.45 A | 0.45 A |
Voltage Pentode - Remote Cutoff (single)
The database records 4BA6 as a possible replacement for4BZ6.
- Not suitable for all circuits
| Specification | Original tube | Replacement |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Remote Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | 7CM | 7CC |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 4.2 V | 4.2 V |
| Heater current | 0.45 A | 0.45 A |
Voltage Pentode - Sharp Cutoff (single)
The database records 4CB6 as a possible replacement for4BZ6.
- Not suitable for all circuits
| Specification | Original tube | Replacement |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Sharp Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | 7CM | Not recorded |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 4.2 V | 4.2 V |
| Heater current | 0.45 A | 0.45 A |
Voltage Pentode - Sharp Cutoff (single)
The database records 4CF6 as a possible replacement for4BZ6.
- Not suitable for all circuits
| Specification | Original tube | Replacement |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Sharp Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | 7CM | Not recorded |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 4.2 V | 4.2 V |
| Heater current | 0.45 A | 0.45 A |
Voltage Pentode - Sharp Cutoff (single)
The database records 4DE6 as a possible replacement for4BZ6.
- Not suitable for all circuits
| Specification | Original tube | Replacement |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Sharp Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | 7CM | Not recorded |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 4.2 V | 4.2 V |
| Heater current | 0.45 A | 0.45 A |
Voltage Pentode - Sharp Cutoff (single)
The database records 4DK6 as a possible replacement for4BZ6.
- Not suitable for all circuits
| Specification | Original tube | Replacement |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Sharp Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | 7CM | Not recorded |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 4.2 V | 4.2 V |
| Heater current | 0.45 A | 0.45 A |
Voltage Pentode - Remote Cutoff (single)
The database records 4JH6 as a possible replacement for4BZ6.
No special restrictions are recorded for this substitution.
| Specification | Original tube | Replacement |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Remote Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | 7CM | 7CM |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 4.2 V | 4.2 V |
| Heater current | 0.45 A | 0.45 A |
Where 4BZ6 can be used as the replacement
In these recorded relationships, 4BZ6 is the replacement tube. The listed original tubes are not automatically suitable as replacements for 4BZ6.
Voltage Pentode - Sharp Cutoff (single)
The database records 4BZ6 as a possible replacement for4AU6.
- Not suitable for all circuits
| Specification | 4BZ6 replacement | Original tube |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Sharp Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | 7CM | 7BK |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 4.2 V | 4.2 V |
| Heater current | 0.45 A | 0.45 A |
Voltage Pentode - Remote Cutoff (single)
The database records 4BZ6 as a possible replacement for4BA6.
- Not suitable for all circuits
| Specification | 4BZ6 replacement | Original tube |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Remote Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | 7CM | 7CC |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 4.2 V | 4.2 V |
| Heater current | 0.45 A | 0.45 A |
Voltage Pentode - Sharp Cutoff (single)
The database records 4BZ6 as a possible replacement for4CB6.
- Not suitable for all circuits
| Specification | 4BZ6 replacement | Original tube |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Sharp Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | 7CM | Not recorded |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 4.2 V | 4.2 V |
| Heater current | 0.45 A | 0.45 A |
Voltage Pentode - Sharp Cutoff (single)
The database records 4BZ6 as a possible replacement for4CF6.
- Not suitable for all circuits
| Specification | 4BZ6 replacement | Original tube |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Sharp Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | 7CM | Not recorded |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 4.2 V | 4.2 V |
| Heater current | 0.45 A | 0.45 A |
Voltage Pentode - Sharp Cutoff (single)
The database records 4BZ6 as a possible replacement for4DE6.
- Not suitable for all circuits
| Specification | 4BZ6 replacement | Original tube |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Sharp Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | 7CM | Not recorded |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 4.2 V | 4.2 V |
| Heater current | 0.45 A | 0.45 A |
Voltage Pentode - Sharp Cutoff (single)
The database records 4BZ6 as a possible replacement for4DK6.
- Not suitable for all circuits
| Specification | 4BZ6 replacement | Original tube |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Sharp Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | 7CM | Not recorded |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 4.2 V | 4.2 V |
| Heater current | 0.45 A | 0.45 A |
Voltage Pentode - Remote Cutoff (single)
The database records 4BZ6 as a possible replacement for4JH6.
No special restrictions are recorded for this substitution.
| Specification | 4BZ6 replacement | Original tube |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Remote Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | 7CM | 7CM |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 4.2 V | 4.2 V |
| Heater current | 0.45 A | 0.45 A |
Verify before substituting
Matching a base or heater voltage is not enough to prove that two tubes are interchangeable. Check pin connections, heater current, maximum ratings, bias requirements, warm-up behavior, and the equipment manufacturer’s service documentation before making a substitution.
View the complete 4BZ6 specifications →