Specialized - Cathode Ray ยทCathodeRay

4096AB

Compact electrostatic cathode-ray instrument tube with a 2.5-inch screen, approximately 2 kV second-anode operation, and published horizontal and vertical deflection sensitivity for waveform display.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
American Small Shell Octal
Socket code
IO
Base pins
8
Nominal heater
2 V / 1.7 A

Description

High-vacuum cathode-ray tube with electrostatic deflection, blue screen, and 800โ€“2,000 V second-anode operation.

Socket description

International Octal

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
American Small Shell Octal
Socket code
IO
Base pins
8
Nominal heater voltage
2 V
Nominal heater current
1.7 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

American Small Shell Octal - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Cathode Ray

X-ray radiationInterelectrode capacitances
Max plate voltage
2000 V

High-vacuum CRT; blue trace.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1937 Standard Valves

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristic

  • SecondAnodeVoltage

    800 to 2000 V

    Published range

Other

  • MaximumFirstAnodeCurrent

    300 uA

    Published datasheet value

Data set 02

1946 Standard Telephone and Cables

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristics

  • Interelectrode capacitances published

    1

    See source table for individual capacitances

Data set 03

1947 Standard Valves

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Other

  • Second anode voltage

    800 to 2000 V

  • Maximum second-anode current

    300 uA

Characteristics

  • Cutoff voltage

    -45 to -35 V

    At second anode 2000 V

  • X sensitivity

    0.13 mm/V

    At 2000 V

  • Y sensitivity

    0.135 mm/V

    At 2000 V

Dimensions

  • Screen diameter

    2.5 in