Data set 01
1937 Standard Valves
Published operating points and test conditions from this source.
Cathode Ray
Construction
Screen color
Blue
Other
Maximum final anode voltage
5000 V
Grid bias cutoff
30 V
Approximate
Specialized - Cathode Ray ·CathodeRay
High-voltage blue-screen cathode-ray instrument tube with electrostatic deflection, a 5 kV final-anode rating, published X/Y sensitivity, and screen-input limits for oscillographic display.
4063AB is a high-vacuum cathode-ray tube; blue screen. The Standard Valves sheet publishes construction, electrical constants, limiting conditions, and applicable operating data.
Special 12-contact base
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
High-vacuum cathode-ray tube.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Screen color
Blue
Maximum final anode voltage
5000 V
Grid bias cutoff
30 V
Approximate
Data set 02
Published operating points and test conditions from this source.
Interelectrode capacitances published
1
See source table for individual capacitances
Data set 03
Published operating points and test conditions from this source.
Maximum anode voltage
5 kV
Maximum screen input power
0.01 W/cm2
Third anode voltage
5 kV
First anode voltage
150 V
X sensitivity
600 mm/V
V = final anode voltage
Y sensitivity
700 mm/V
V = final anode voltage