Data set 01
1937 Standard Valves
Published operating points and test conditions from this source.
Cathode Ray
Characteristics
Filament current range
700 mA to 1.1 A
Anode voltage range
300 to 2000 V
Normal anode voltage
350 V
Deflecting-plate pair capacitance
5.5 pF
Including socket
Single deflecting plate to anode capacitance
7.8 pF
Including socket
Deflecting-plate pair conductance
1 umho
Approximate
Shield voltage range
0 to 50 V
From potentiometer
Sensitivity
260 mm/V
Approximate
Screen characteristic
green spot for visual work