Skip to main content

Specialized - Cathode Ray ·CathodeRay

4018AB

Early electrostatic cathode-ray oscillograph tube with a blue photographic screen, intended for measurement display; manufacturer data specifies deflection sensitivity and operation over roughly 300–2000 V anode supply.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
BRITISH9
Base pins
-
Nominal heater
0.75 V / 900 mA

Description

Standard Valves 4018AB is a gas-filled cathode-ray tube specified for replacement service. It operates over a 300-2000 V anode range with 350 V normal anode voltage and a 0-50 V shield supply. Its screen characteristic is blue photographic spot. One plate of each deflecting-plate pair is connected to the anode.

Socket description

Standard British 9-contact base

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
BRITISH9
Base pins
-
Nominal heater voltage
0.75 V
Nominal heater current
900 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Cathode Ray

X-ray radiationInterelectrode capacitances
Max plate voltage
2000 V

Published ratings/characteristics promoted; remaining useful source values represented as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1937 Standard Valves

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristics

  • Filament Current Range

    700 mA to 1.1 A

    Published range

  • Anode Voltage Range

    300 to 2000 V

    Published range

  • Normal Anode Voltage

    350 V

    Published specification

  • Shield Voltage Range

    0 to 50 V

    From a potentiometer

Other

  • Protective Resistance

    2000 ohm

    Include in shield circuit and anode circuit

  • Replacement Type

    4050-AB

    Published specification

Construction

  • Screen Characteristic

    Blue spot for photographic work

    Published specification

  • Deflection Plate Connection

    One plate of each deflecting pair is connected to the anode

    Published specification

Data set 02

1946 Standard Telephone and Cables

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristics

  • Heater/filament voltage

    0.75 V

  • Heater/filament current

    900 mA

Other

  • Maximum direct anode voltage

    2000 V

  • Anode voltage range

    300–2000 V

  • Normal anode voltage

    350 V

  • Shield voltage range

    0–50 V