Skip to main content

Specialized - Cathode Ray ·CathodeRay

3AQP1

Three-inch oscilloscope and instrument cathode-ray tube with electrostatic focusing and electrostatic deflection and a P1 screen. Manufacturer documentation supports compact waveform, measurement, and indicator-display service.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
OCTALCRT8
Base pins
-
Nominal heater
6.3 V / 600 mA

Description

Electrostatically focused and deflected oscilloscope/instrument CRT with P1 phosphor.

Socket description

Octal 8-contact CRT base

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
OCTALCRT8
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
600 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Cathode Ray

X-ray radiationInterelectrode capacitances
Max plate voltage
2500 V
Max screen voltage
550 V

Electrostatic-focus/electrostatic-deflection CRT.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1950 Sylvania

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristics

  • Focusing method

    Electrostatic

  • Deflection method

    Electrostatic

  • Phosphor

    P1

Data set 02

1965 Sylvania Electronic Tubes Vol3

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Characteristics

  • Focusing method

    Electrostatic

  • Deflection method

    Electrostatic

  • Heater voltage

    6.3 V

  • Heater current

    600 mA

  • Fluorescence

    Green

Application

  • Application

    Oscilloscope / precision instrument display

Other

  • Anode-2 voltage maximum

    3000 V

  • Anode-2 input maximum

    6 W

  • Anode-1 focus voltage maximum

    1200 V

  • Typical anode-2 voltage

    2000 V

  • Focus voltage range

    330 to 620 V

  • Grid cutoff voltage range

    -58 to -135 V

Data set 03

1971 RCA HB3 Binder 1 of 7

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Other

  • Heater voltage

    6.3 V

  • Heater current

    600 mA

  • Peak heater-cathode voltage, heater negative

    125 V

  • Maximum deflecting electrode voltage

    550 V

  • Focusing electrode voltage minimum

    165 V

    Typical

  • Focusing electrode voltage maximum

    775 V

    Typical

Construction

  • Focusing method

    Electrostatic

  • Deflection method

    Electrostatic

  • Phosphor

    P1

Characteristic

  • Fluorescence

    Yellowish-Green

  • Persistence

    Medium

Capacitance

  • Grid #1 to all other electrodes capacitance

    8 pF

    Approximate

Application

  • Application

    Oscillograph/cathode-ray display