Data set 01
9999 Mixed 2000
Published operating points and test conditions from this source.
Cathode Ray
Other
Plate voltage
1000 V
Typical first/third anode voltage
Specialized - Cathode Ray ·CathodeRay
3AFP1 high-sensitivity green P1 oscilloscope cathode-ray tube with electrostatic focus and X/Y deflection, 6.3 V 0.55 A heater.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
CRT first and third anodes maximum 1500 V (minimum 700 V, design-centre minimum 800 V), second anode maximum 500 V, maximum difference 1200 V. Peak total anode dissipation 2 W (not ordinary amplifier plate dissipation). Typical first/third anodes 1000 V; focusing second anode 210–320 V; grid visual cutoff -28 to -65 V. X deflection 20 V/cm, Y deflection 11.5 V/cm. Screen P1 green, medium persistence. Grid resistor max 1 MΩ. Source: ETEL 1957.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Plate voltage
1000 V
Typical first/third anode voltage