Skip to main content

Specialized - Cathode Ray ·CathodeRay

31E14

Fourteen-inch rectangular cathode-ray tube for television studio monitoring, using low-voltage electrostatic focus and 70-degree magnetic deflection. Manufacturer documentation warns that X-ray shielding may be necessary above 16 kV.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
B12A
Socket code
-
Base pins
12
Nominal heater
6.3 V / 300 mA

Description

A 14-inch diagonal rectangular cathode-ray tube with 70-degree magnetic deflection and low-voltage electrostatic focusing, intended for television studio monitoring equipment. The datasheet warns that X-ray shielding may be necessary above 16 kV.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
B12A
Socket code
-
Base pins
12
Nominal heater voltage
6.3 V
Nominal heater current
300 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

B12A - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Cathode Ray

X-ray radiationInterelectrode capacitances
Max plate voltage
16000 V

CRT electrode ratings and operating data preserved in parameter rows.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1961 AEI Industrial Valves

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Other

  • MaximumSecondFourthAnodeVoltage

    16 kV

    DesignCentre; absolute maximum 20 kV

  • MinimumSecondFourthAnodeVoltage

    10 kV

  • MaximumThirdAnodeVoltage

    -500 to 500 V

  • MaximumFirstAnodeVoltage

    500 V

  • Maximum Heater Cathode Voltage

    180 V

    HeaterNegative DC

  • Maximum Peak Heater Cathode Voltage

    400 V

    HeaterNegative; warming-up period not exceeding one minute

  • TypicalSecondFourthAnodeVoltage

    12 kV

  • TypicalFirstAnodeVoltage

    300 V

  • TypicalThirdAnodeFocusVoltage

    -300 to 300 V

    Focus range

  • GridBiasCutoff

    -72 to -30 V

    Raster cut-off

  • PeakToPeakModulatingVoltage

    24 V

    Modulation up to 150 uA

Characteristic

  • Grid To All Other Electrodes Capacitance

    9 pF

    Includes CRT92/7 holder

  • Cathode To All Other Electrodes Capacitance

    7 pF

    Includes CRT92/7 holder

  • SecondFourthAnodeToExternalCoatingCapacitance

    1300 pF

    Approximate; includes CRT92/7 holder

  • Deflection Angle

    70 degree

    Magnetic deflection

  • ScreenDiagonal

    14 in

    Rectangular face

Data set 02

1961 Associated Electrical Industries

Published operating points and test conditions from this source.

SECTION 1

Cathode Ray

Other

  • MinimumSecondFourthAnodeVoltage

    10 kV

  • MaximumThirdAnodeVoltage

    500 V

  • MaximumFirstAnodeVoltage

    500 V

  • Maximum Heater Cathode Voltage

    180 V

    HeaterNegative

  • Peak Heater Cathode Voltage

    400 V

    WarmupMaximum1Minute

  • TypicalSecondFourthAnodeVoltage

    12 kV

Characteristics

  • GridAllCapacitance

    90 pF

  • CathodeAllCapacitance

    70 pF