Data set 01
1961 AEI Industrial Valves
Published operating points and test conditions from this source.
Cathode Ray
Other
MaximumSecondAndFourthAnodeVoltageDesignCentre
15000 V
AbsoluteMaximumSecondAndFourthAnodeVoltage
18000 V
MinimumSecondAndFourthAnodeVoltage
8000 V
MaximumThirdAnodeVoltage
700 V
MaximumFirstAnodeVoltage
500 V
Maximum Heater Cathode Voltage
200 V
Maximum Peak Heater Cathode Voltage
400 V
TypicalSecondAndFourthAnodeVoltage
12000 V
TypicalFirstAnodeVoltage
400 V
TypicalThirdAnodeVoltageForFocus
200 V
GridBiasForCutoff
-72 to -30 V
Capacitance
GridToAllCapacitanceBalanced
7 pF
GridToAllCapacitanceWithHolder
8.5 pF
CathodeToAllCapacitanceBalanced
3 pF
CathodeToAllCapacitanceWithHolder
3.5 pF
FinalAnodesToExternalCoatingCapacitance
400 pF