Data set 01
1961 AEI Industrial Valves
Published operating points and test conditions from this source.
Cathode Ray
Other
MaximumSecondAndFourthAnodeVoltageDesignCentre
16000 V
AbsoluteMaximumSecondAndFourthAnodeVoltage
18000 V
MinimumSecondAndFourthAnodeVoltage
8000 V
MaximumThirdAnodeVoltage
500 V
MaximumFirstAnodeVoltage
500 V
Maximum Heater Cathode Voltage
200 V
Maximum Peak Heater Cathode Voltage
400 V
TypicalSecondAndFourthAnodeVoltage
12000 V
TypicalFirstAnodeVoltage
300 V
GridBiasForCutoff
-72 to -30 V
Capacitance
GridToAllCapacitance
9 pF
Cathode To All Capacitance
7 pF