Data set 01
1960 Mazda
Published operating points and test conditions from this source.
Cathode Ray
Other
Maximum first-anode voltage
2500 V
Maximum second-anode voltage
1000 V
Maximum third-anode voltage
6000 V
Specialized - Cathode Ray ·CathodeRay
All-electrostatic precision-measurement cathode-ray tube with a polished flat face. Mazda and AEI documentation identify it for accurate laboratory and industrial trace presentation rather than television picture service.
All-electrostatic precision-measurement cathode-ray tube with polished flat face.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 0
No fixed ratings are recorded for this section.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Maximum first-anode voltage
2500 V
Maximum second-anode voltage
1000 V
Maximum third-anode voltage
6000 V
Data set 02
Published operating points and test conditions from this source.
MaximumFirstAnodeVoltage
2500 V
MaximumSecondAnodeVoltage
1000 V
MaximumThirdAnodeVoltage
6000 V
TypicalThirdAnodeVoltage
3000 to 5000 V
TypicalFirstAnodeVoltage
2000 V
GridBiasForCutoff
-60 V
XPlateSensitivityAt3000V
0.2 mm/V
XPlateSensitivityAt5000V
0.14 mm/V
YPlateSensitivityAt3000V
0.42 mm/V
YPlateSensitivityAt5000V
0.28 mm/V
X1ToAllCapacitance
18 pF
X2ToAllCapacitance
15 pF
Y1ToAllCapacitance
14.5 pF
Y2ToAllCapacitance
14.5 pF
GridToAllCapacitance
9.5 pF
Data set 03
Published operating points and test conditions from this source.
MaximumFirstAnodeVoltage
2500 V
MaximumSecondAnodeVoltage
1000 V
MaximumThirdAnodeVoltage
6000 V
TypicalThirdAnodeVoltage
3000 to 5000 V
TypicalFirstAnodeVoltage
2000 V
GridBiasForCutoff
-60 V
XPlateSensitivityAt3000V
0.2 mm/V
XPlateSensitivityAt5000V
0.14 mm/V
YPlateSensitivityAt3000V
0.42 mm/V
YPlateSensitivityAt5000V
0.28 mm/V
X1ToAllCapacitance
18 pF
X2ToAllCapacitance
15 pF
Y1ToAllCapacitance
14.5 pF
Y2ToAllCapacitance
14.5 pF
GridToAllCapacitance
9.5 pF