Skip to main content

Voltage - Dual Triode (similar) ·Triode-Triode

2C50

Low-power double triode designed particularly for discriminator circuits in servo amplifiers, providing paired triode sections for control and instrumentation applications.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
2
Base
8BD
Socket code
IO
Base pins
8
Nominal heater
12.6 V / 300 mA

Description

Low-power double triode designed particularly for discriminator circuits of servo amplifiers.

Socket description

International Octal

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
8BD
Socket code
IO
Base pins
8
Nominal heater voltage
12.6 V
Nominal heater current
300 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

8BD - Terminal pinout

Electrical assignments shared by every tube using this base designation.

TerminalSectionConnectionEvidence
PIN12G1BG1 — Control Grid

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 129, 8BD

PIN22PBP — Plate (Anode)

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 129, 8BD

PIN32KBK — Cathode

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 129, 8BD

PIN41G1AG1 — Control Grid

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 129, 8BD

PIN51PAP — Plate (Anode)

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 129, 8BD

PIN61KAK — Cathode

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 129, 8BD

PIN7H—H — Heater

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 129, 8BD

PIN8H—H — Heater

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 129, 8BD

Section ratings

2 physical sections, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.00175 S
Amplification factor
9.5
Max plate voltage
800 V
Max plate dissipation
3.85 W
Max cathode current
30 mA

Representative row for two identical triode sections; tabulated operating values apply to each unit.

Section 2

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.00175 S
Amplification factor
9.5
Max plate voltage
800 V
Max plate dissipation
3.85 W
Max cathode current
30 mA

Second physical triode restored under current section policy.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1938 Raytheon

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • HeaterVoltageNominal

    12.6 V

    Nominal

  • HeaterCurrentNominal

    300 mA

    Nominal

  • Maximum Plate Voltage

    800 V

  • Maximum Plate Dissipation

    3.85 W

  • Maximum Cathode Current

    30 mA

Characteristic

  • Amplification Factor

    10

    Typical

Data set 02

195X Raytheon Special Purpose Tubes

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Plate Voltage

    300 V

  • Grid 1 Voltage

    -24 V

  • Plate Current

    12.5 mA

Characteristic

  • Transconductance

    1750 uS

    EachUnit

  • Amplification Factor

    9.5

    EachUnit