Data set 01
1971 RCA HB3 Binder 1 of 7
Published operating points and test conditions from this source.
Cathode Ray
Characteristics
I 10° MAGNETIC DEFLECTION
10 V
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Grid No.1 to all other electrodes
6 pF
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
,~"~ — published value 1
1700 mA
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
,~"~ — published value 2
2500 mA
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Heater Current at 6.3 V — published value 1
6.3 mA
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Heater Current at 6.3 V — published value 2
450 mA
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Heater Current at 6.3 V — published value 3
20 mA
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Light transmission a; center (Approx.)
42
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Projected Area of Screen
282
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
PI n 1 —Heater
1
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Pln 3 -Grid ho.2
3
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Anode Voltage — published value 1
12000 V
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Anode Voltage — published value 2
22000 V
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Grid-No.2 Voltage — published value 1
30 V
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Grid-No.2 Voltage — published value 2
70 V
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Heater Voltage — published value 1
5 V
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Heater Voltage — published value 2
7 V
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Heater Voltage — published value 3
6.9 V
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Combined AC & DC voltage
200 V
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Anode Voltage
16000 V
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Grid-No.4 Voltage — published value 1
0 V
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Grid-No.4 Voltage — published value 2
400 V
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Grid-No.2 Voltage
50 V
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Cathode Voltage — published value 1
32 V
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Cathode Voltage — published value 2
50 V
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.
Grid-No. l Circuit Resistance
1.5 mA
Published CRT datasheet value; multiple numbers on one source row represent separate limits or operating conditions.