Data set 01
1964 RMA EIA
Published operating points and test conditions from this source.
Cathode Ray
Application
Application
Cathode-ray display / television / instrumentation
Characteristics
Focusing method
Electrostatic
Deflection method
Magnetic
Horizontal deflection angle
99 deg
Vertical deflection angle
82 deg
Diagonal deflection angle
110 deg
Heater warm-up time
11 s
Capacitance
Cathode-to-all capacitance
4 pF
Grid1-to-all capacitance
5 pF
External coating capacitance minimum
2000 pF
External coating capacitance maximum
2500 pF
Other
Anode voltage minimum
11000 V
Focus-electrode positive voltage maximum
1250 V
Focus-electrode negative voltage minimum
-400 V
Grid2 voltage minimum
40 V
Grid2 voltage maximum
80 V
Grid1 negative voltage maximum
-154 V
Grid1 negative peak maximum
-220 V
Grid1 positive peak maximum
2 V
Heater voltage minimum
5.7 V
Heater voltage maximum
6.9 V
Heater-cathode voltage during warm-up maximum
450 V
Heater-cathode voltage after warm-up maximum
300 V
Typical anode voltage
18000 V
Typical focus voltage
150 V
Typical grid2 voltage
50 V
Cathode cutoff voltage range
+33 to +45 V
Grid1 circuit resistance maximum
1.5 Mohm