Data set 01
1964 RMA EIA
Published operating points and test conditions from this source.
Cathode Ray
Construction
Gun count
3
Focus lens
Bipotential
Phosphor revision
P22 rare-earth red phosphor
Characteristics
Focusing method
Electrostatic
Convergence method
Magnetic
Deflection method
Magnetic
Diagonal deflection angle
92 deg
Horizontal deflection angle
80 deg
Vertical deflection angle
68 deg
Heater voltage nominal
6.3 V
Heater current
1.35 A
Capacitance
Grid1 capacitance per gun
16 pF
All-cathodes capacitance
10 pF
Focus-electrode capacitance
12 pF
External coating capacitance minimum
1800 pF
Other
Anode voltage maximum
27500 V
Anode voltage minimum
20000 V
Heater voltage maximum
6.9 V
White-current share red
27 %
White-current share blue
33 %
White-current share green
40 %
X-radiation data
Not available in registration update
Application
Application
Color television picture display