Data set 01
1950 Sylvania
Published operating points and test conditions from this source.
Cathode Ray
Characteristics
Phosphor
P4
Deflection method
Magnetic
Focusing method
Tri-potential electrostatic
Specialized - Cathode Ray ·CathodeRay
Twenty-one-inch direct-view monochrome television picture tube with magnetic deflection and high-voltage operation. Manufacturer documentation describes its focusing system, picture-screen construction, and receiver-display characteristics for large-screen television service.
The 21FAP4 is a 21-inch television cathode-ray tube with magnetic deflection and P4 phosphor.
Small-button Neoeightar 7-contact CRT base family
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Direct-view CRT; maximum anode voltage promoted. Source warns of possible X-radiation exposure above specified voltage conditions.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Phosphor
P4
Deflection method
Magnetic
Focusing method
Tri-potential electrostatic
Data set 02
Published operating points and test conditions from this source.
Heater Voltage
6.3 V
Heater Current
600 mA
Focusing Method
Electrostatic text
Deflection Method
Magnetic text
Phosphor
P4 text
Fluorescence
White text
Persistence
Medium Short text
Maximum Anode Voltage
25000 V
RepresentativeFamilyLimit
Typical Anode Voltage
18000 V
RepresentativeFamilyOperatingPoint
Maximum Grid2 Voltage
700 V
RepresentativeFamilyLimit
Maximum Grid1 Negative Bias
220 V
RepresentativeFamilyLimit
Maximum Heater-Cathode Voltage
200 V
AfterWarmup
Maximum Grid1 Circuit Resistance
1.5 Mohm