Data set 01
1958 Compagnie General
Published operating points and test conditions from this source.
Rectifier
Other
Peak Inverse Voltage
15000 V
Maximum Supply Frequency
200 kHz
Rectifier - TV Line Scan Boost ·Rectifier
High-voltage low-current half-wave vacuum rectifier with a thoriated-tungsten filament. Its compact construction and multi-kilovolt capability suit specialized high-voltage power supplies.
High-voltage low-current vacuum rectifier with thoriated-tungsten filament for compact high-voltage power supplies.
Small-button Noval 9-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Directly heated half-wave high-voltage rectifier with a 20 kV peak-inverse-voltage rating.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Peak Inverse Voltage
15000 V
Maximum Supply Frequency
200 kHz
Data set 02
Published operating points and test conditions from this source.
Maximum inverse voltage
20000 V
HalfWaveRectifier
Maximum DC output current
2 mA
HalfWaveRectifier
Maximum peak current
10 mA
HalfWaveRectifier
Forward voltage drop
50 V
HalfWaveRectifier; At 5 mA DC
Data set 03
Published operating points and test conditions from this source.
Heater voltage
1.25 V
Nominal
Heater current
265 mA
Nominal
Data set 04
Published operating points and test conditions from this source.
Filament voltage
1.25 V
Filament current
265 mA
Maximum steady-state peak plate current
5.5 mA
HighVoltageRectifier
Maximum DC output current
3.5 mA
HighVoltageRectifier
Minimum filament heating time
0 s