Data set 01
1971 RCA HB3 Binder 1 of 7
Published operating points and test conditions from this source.
Cathode Ray
Other
Heater voltage
6.3 V
Heater current
600 mA
Heater warm-up time
11 s
Maximum anode/ultor voltage
23000 V
Minimum anode/ultor voltage
11000 V
Typical anode/ultor voltage
16000 V
PictureTubeService
Maximum grid No.2 voltage
550 V
Typical grid No.2 voltage
300 V
PictureTubeService
Focus-voltage range minimum
0 V
OptimumFocus
Focus-voltage range maximum
400 V
OptimumFocus
Visual-extinction voltage range minimum
28 V
FocusedRasterExtinction
Visual-extinction voltage range maximum
62 V
FocusedRasterExtinction
Maximum grid No.1 circuit resistance
1.5 megohm
X-ray shielding warning
Present
HighAnodeVoltage
Maximum negative grid No.1 peak voltage
220 V
Maximum negative grid No.1 bias magnitude
155 V
Maximum positive grid No.1 peak voltage
2 V
Peak heater-cathode voltage during warm-up
450 V
HeaterNegative;Warmup<=15s
Peak heater-cathode voltage after warm-up
300 V
HeaterNegative
Peak heater-cathode voltage heater positive
200 V
HeaterPositive
Adjustable centering magnet field strength maximum
8 gauss
Approximate
Construction
Focusing method
LowVoltageElectrostatic
Deflection method
Magnetic
Phosphor
P4
Screen type
White
P4
Ion-trap magnet required
No
Characteristic
Deflection angle
114 deg
Approximate
Capacitance
Cathode to all other electrodes capacitance
5 pF
Approximate