Data set 01
1940 RCA
Published operating points and test conditions from this source.
Cathode Ray
Application
Application
TelevisionPictureTube text
Characteristic
ScreenDiagonal
14 in
Specialized - Cathode Ray ·CathodeRay
Fourteen-inch P4 television picture tube using magnetic focusing and deflection, with white fluorescence, approximately 70-degree deflection, and typical 12 kV anode operation.
An indirectly heated, rectangular picture tube featuring magnetic focus, magnetic deflection, and an ion-trap gun for television receiver applications.
The 14EP4 is a short, directly viewed, rectangular picture tube (kinescope) designed for use in television receivers. It features magnetic focus, magnetic deflection, a high-efficiency white fluorescent screen, and an ion-trap gun requiring an external single-field magnet. The tube's rectangular design allows for full reproduction of the transmitted television picture without wasting screen area, enabling more compact cabinet designs with approximately 20 percent less height than a round-face tube of equivalent picture width. This design also allows the receiver chassis to remain flat without requiring a cutout or depression beneath the tube face.
The 14EP4 incorporates a rectangular glass bulb with a nominal picture area of 11-3/8" by 8-1/2" (with some specifications defining a raster size of 11-1/2" by 8-5/8"). The faceplate is constructed of Filterglass, which contains a neutral light-absorbing material. This material reduces ambient-light reflections from the phosphor and internal reflections within the faceplate itself at a much higher ratio than it reduces the directly viewed light of the picture, thereby significantly improving contrast under high ambient light conditions. The faceplate light transmission is rated between 65% and 66%.
The screen utilizes Phosphor No. 4-Sulfide Type, which exhibits white fluorescence and phosphorescence with a color temperature of approximately 7000 K. The phosphor has medium persistence, with its brightness not exceeding 7% of the peak value 33 milliseconds after excitation is removed.
Key physical dimensions of the 14EP4 include:
The 14EP4 is equipped with an indirectly heated, coated unipotential cathode. The heater is designed to operate on either AC or DC.
| Heater Parameter | Value |
|---|---|
| Heater Voltage | 6.3 V |
| Heater Current | 0.6 A |
The tube uses a Small-Shell Duodecal 5-Pin base (JETEC No. B5-57), which can fit either a duodecal 12-contact socket or a duodecal 5-contact segment socket. The socket should not be rigidly mounted and must have flexible leads to allow free movement.
The pin connections, viewed from the bottom of the base, are as follows:
The tube features both internal and external conductive coatings. The external conductive coating, when properly grounded, forms a high-voltage filter capacitor with the internal conductive coating on the bulb wall.
| Direct Interelectrode Capacitances | Value |
|---|---|
| Grid No. 1 to all other electrodes | 6 µµF |
| Cathode to all other electrodes | 5 µµF |
| External conductive coating to Anode | 750 min to 2000 max µµF (typically 1250 µµF) |
The maximum ratings for the 14EP4 are established under the design-center system (and interpreted according to RMA Standard MB-210):
| Parameter | Maximum Rating |
|---|---|
| Anode Voltage | 14,000 V |
| Grid No. 2 Voltage | 410 V |
| Grid No. 1 Negative Bias Voltage | 125 V |
| Grid No. 1 Positive Bias Voltage | 0 V |
| Grid No. 1 Positive Peak Voltage | 2 V |
| Peak Heater-Cathode Voltage (Heater negative to cathode during warm-up ≤ 15s) | 410 V |
| Peak Heater-Cathode Voltage (Heater negative to cathode after warm-up) | 150 to 180 V |
| Peak Heater-Cathode Voltage (Heater positive to cathode) | 150 to 180 V |
| Grid No. 1 Circuit Resistance | 1.5 MΩ |
Under typical operating conditions, the tube is operated with an anode voltage of 12,000 V and a Grid No. 2 voltage of 300 V. The Grid No. 1 voltage required for visual extinction of the undeflected focused spot ranges from -33 V to -77 V.
For focusing and beam alignment, the following typical values apply:
Because of the short overall length of the 14EP4, the electron beam must be deflected through wide angles to scan the screen area. The nominal deflection angles are:
The deflecting yoke must have an effective length of not more than 1-11/16" and be designed so that the effective center of deflection is approximately 1.15 inches from the Reference Line. This prevents the electron beam from striking the neck of the tube.
The focusing field (supplied by an electromagnetic coil, permanent magnet, or a combination) must be spaced at least 1/2 inch from the end of the deflecting-coil windings to minimize interaction. The ion-trap magnet must be positioned in the region of Grid No. 2, with its north pole adjacent to vacant pin position No. 8 and its south pole to pin No. 2. It must be adjusted promptly upon applying operating voltages to obtain maximum raster brightness; operating the tube with an improperly aligned ion-trap magnet can cause rapid damage to the gun structure.
To protect the tube electrodes from damage due to high-voltage surges or internal arcing, the power supply should have inherent regulation limiting the continuous short-circuit current to 5 mA. If the supply can deliver an instantaneous short-circuit current exceeding 1 ampere or store more than 250 microcoulombs of charge, minimum series limiting resistances must be added:
Additionally, the product of the anode voltage and the average anode current must be limited to 6 watts, with peak anode current restricted to 1 mA and average anode current to 0.250 mA.
Safety precautions must be strictly observed when operating the 14EP4. The tube contains a high vacuum and poses an implosion hazard; it should be handled with care and protected by a shatter-proof clear cover over the face of the receiver. High-voltage terminals must be enclosed, and interlocking switches should be used. When operated within its maximum ratings, the tube does not produce harmful x-ray radiation. However, if operated above 16 kV (absolute value), special shielding precautions against x-rays may be required. To prevent sparking, corona, and leakage currents, the uncoated glass surface around the anode cap must be kept clean, dry, and free of dust or fingerprints.
The 14EP4 is a compact, rectangular television picture tube utilizing magnetic focus and magnetic deflection with a 70° diagonal deflection angle. It features a 6.3 V, 0.6 A heater, a high-efficiency Phosphor No. 4-Sulfide Type white screen, and a Filterglass faceplate designed to maximize picture contrast under ambient light. Operating at a typical anode voltage of 12,000 V, the 14EP4 requires a single-field ion-trap magnet and careful alignment of its focusing and deflecting components to ensure uniform focus and prevent damage to its internal structure.
Duodecar 12-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
CRT-specific electrode/focus/deflection values retained in parameter rows.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Application
TelevisionPictureTube text
ScreenDiagonal
14 in
Data set 02
Published operating points and test conditions from this source.
Maximum Anode Voltage
14000 V
Typical Anode Voltage
12000 V
Maximum Grid2 Voltage
410 V
Typical Grid2 Voltage
300 V
FocusingMethod
Magnetic
DeflectingMethod
Magnetic
DeflectionAngleApproximate
70 degree
PhosphorNumber
4
FluorescentColor
White