Data set 01
1968 General Electric Co
Published operating points and test conditions from this source.
Cathode Ray
Other
Third Anode Voltage Maximum
1700 V
Typical Fourth Anode Voltage
4000 V
TypicalOperation
Specialized - Cathode Ray ·CathodeRay
Rectangular flat-faced single-gun oscilloscope CRT with spiral post-deflection acceleration and an aluminum-backed screen. Its approximately 8 × 10 cm display area is intended for bright, sharply defined oscillographic instrument traces.
The 1400C is an 8 × 10 cm flat-faced, single-gun cathode-ray oscilloscope tube designed for precision display applications. Manufactured by The M-O Valve Co. Ltd. (a member of the G.E.C. group), this tube features a spiral post-deflection accelerator (p.d.a.), a thin aluminum-backed screen, and direct side-pin connections for the deflection plates to minimize input capacitance and optimize high-frequency performance.
The 1400C is built with a rectangular faceplate and a specialized envelope designed to facilitate precise waveform measurement. The physical dimensions and screen properties are tightly controlled:
The tube utilizes a thin aluminum-backed screen that provides high brightness and prevents charge buildup. The standard phosphor configuration is G.E.C. type 74, which corresponds to the E.I.A. phosphor code P31.
| Parameter | Specification |
|---|---|
| Fluorescence | Green |
| Phosphorescence | Green |
| Persistence | 1–5 ms |
| Line Width (Typical) | 0.7 mm (measured at the geometric center with a 5 µA beam current) |
The 1400C can be mounted in any physical orientation. However, it must not be supported by its electrical base alone. The recommended mounting method is to hold the tube in a suitable rubber mask at the screen end and secure it with a clamp around the magnetic shield near the base. The mounting socket must have sufficient freedom of movement to accommodate tolerances in overall length and base orientation.
Because the electron beam is highly sensitive to external disturbances, the tube must not be exposed to strong magnetic fields during operation or storage.
The tube utilizes a B12F base (conforming to BS 448) for primary gun connections, a CT8 side contact for the final post-deflection accelerator anode (), and four dedicated side pins on the neck for the deflection plates.
The base pins provide connections to the heater, cathode, control grid, and focusing anodes:
| Pin | Connection | Description |
|---|---|---|
| 1 | Control grid | |
| 2 | Cathode | |
| 3 | Heater | |
| 4 | Heater | |
| 5 | Focusing anode | |
| 6 | First anode | |
| 7 | Blanking electrode | |
| 8 | Astigmatism/interplate shield anode | |
| 9 | IC | Internal connection (do not connect) |
| 10 | IC | Internal connection (do not connect) |
| 11 | Pattern correction electrode | |
| 12 | IC | Internal connection (do not connect) |
The final anode () is connected via a CT8 side contact (conforming to BS 448), positioned such that its center lies within 2 mm of the major axis of the faceplate.
The deflection plates are connected via four side pins located on the neck. When viewed from the base and reading clockwise from base pin 9, the side pins are arranged in the sequence: , , , . These pins are contained within a 92° zone, with a minimum spacing of 6 mm between adjacent pins, a pin diameter of 1 mm, and a minimum pin length of 3.0 mm.
When looking directly at the screen with base pins 6 and 7 positioned uppermost:
To facilitate proper electrical and mechanical installation, the following accessories are specified:
The 1400C features an indirectly heated cathode. All voltage ratings are referenced to the cathode unless otherwise specified.
| Parameter | Rating Type | Minimum | Maximum | Unit |
|---|---|---|---|---|
| Heater Voltage () | Nominal | — | 6.3 | V |
| Heater Current () | Nominal | — | 0.3 | A |
| Final Anode Voltage () | Absolute | 3.5 | 7.0 | kV |
| Interplate Shield Voltage () | Absolute | 0.6 | 1.7 | kV |
| Voltage Ratio () | Absolute | — | 4.0 | Ratio |
| Focusing Anode Voltage () | Absolute | 0 | 1.0 | kV |
| First Anode Voltage () | Absolute | 0.6 | 1.75 | kV |
| Control Grid Voltage () | Absolute | 1.0 | 200 | V |
| Blanking Grid to First Anode Voltage () | Absolute | -200 | +200 | V |
| Y-Plate to Anode 3 Voltage () | Absolute | — | 500 | V |
| X-Plate to Anode 3 Voltage () | Absolute | — | 500 | V |
| Heater-to-Cathode Voltage () | Absolute | — | ±150 | V |
| Grid 1 to Cathode Resistance () | Absolute | — | 1.5 | MΩ |
| Y-Plate to Anode 3 Resistance () | Absolute | — | 100 | kΩ |
| X-Plate to Anode 3 Resistance () | Absolute | — | 500 | kΩ |
Under typical operating conditions, the tube is configured with a post-deflection acceleration voltage of 4 kV and an interplate shield voltage of 1 kV.
For circuit design, the required voltage ranges are scaled relative to the anode voltages:
The 1400C provides a highly linear and well-defined display area with minimal distortion.
The typical capacitances of the tube electrodes are as follows:
| Capacitance | Value |
|---|---|
| 4.4 pF | |
| 9.3 pF | |
| 10.0 pF | |
| 1.2 pF | |
| 2.7 pF | |
| 3.0 pF | |
| 2.1 pF | |
| 4.1 pF | |
| 4.1 pF |
The 1400C is a high-performance, flat-faced, single-gun oscilloscope tube featuring an 8 × 10 cm display area, a spiral post-deflection accelerator, and a P31 green phosphor screen. Operating with a typical final anode voltage of 4 kV and an interplate shield voltage of 1 kV, it provides deflection factors of 8.5 V/cm (Y-axis) and 15.5 V/cm (X-axis). The tube incorporates dedicated electrodes for astigmatism correction, pattern correction, and beam blanking, alongside an external axis alignment coil capability. Housed in a B12F base with direct side-pin connections for the deflection plates, the 1400C is optimized for precise, low-distortion waveform visualization in professional test and measurement equipment.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 0
Fourth anode absolute maximum 7.0 kV.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Third Anode Voltage Maximum
1700 V
Typical Fourth Anode Voltage
4000 V
TypicalOperation