Skip to main content

Specialized - Cathode Ray ·CathodeRay

12XP4

12-inch monochrome television cathode-ray picture tube with magnetic focus, magnetic deflection and ion trap; 6.3 V, 0.3 A heater.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
B12A
Socket code
-
Base pins
12
Nominal heater
6.3 V / 300 mA

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
B12A
Socket code
-
Base pins
12
Nominal heater voltage
6.3 V
Nominal heater current
300 mA
Parallel heater voltage
6.3 V
Parallel heater current
300 mA
Series capable
Yes

B12A - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Cathode Ray

X-ray radiationInterelectrode capacitances
Max plate voltage
9000 V

CRT second anode (a2) maximum 9 kV; typical 8 kV. First anode (a1) typical 250 V. 6 pF grid-to-all, 5 pF cathode-to-all, approximately 2000 pF second anode-to-external coating. Other limits in source have OCR ambiguity; do not interpret a2 voltage as ordinary amplifier plate rating.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

No source-specific operating conditions are recorded.