- Base
- —
- Socket code
- —
- Electrical Summary
- -
- Sections
- 1
RCA protective breakdown tube for AC circuits, conducting when voltage exceeds its threshold to protect associated equipment from excessive voltage.
RCA protective breakdown tube for AC circuits, conducting when voltage exceeds its threshold to protect associated equipment from excessive voltage.
RCA protective breakdown tube for higher-voltage AC circuits, conducting at a defined threshold to protect associated equipment from excessive voltage.
| Ik max | 30 mA |
|---|
Gas-discharge protective tube that breaks down near 160 V to protect circuits against excessive voltage.
Two-electrode gas-filled spark-gap protective tube with approximately 1 kV initial breakdown voltage, intended for overvoltage protection rather than commanded pulse switching.
Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold.
Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold.
Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold.
Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold.
Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold.
Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold.
Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold.
Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold.
Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold.
Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold.
Neon-helium gas-filled telephone-line surge protector. Gas breakdown diverts damaging overvoltage transients away from communications equipment without requiring a heater.
Bendix cold-cathode sealed spark gap for high-voltage overvoltage protection. Gas breakdown diverts damaging transients away from protected equipment.
Bendix cold-cathode sealed spark gap for high-voltage overvoltage protection. Gas-discharge breakdown safely shunts damaging voltage surges.
Rare-gas-filled low-voltage surge arrester for protecting low-current installations and cables against lightning, atmospheric overvoltages, and accidental contact with power lines.
Inert-gas surge arrester designed to protect aerial lines and cables against lightning and atmospheric overvoltages by conducting when transient voltage exceeds its protective threshold.
Inert-gas surge arrester designed to protect aerial lines and cables against lightning and atmospheric overvoltages by conducting when transient voltage exceeds its protective threshold.
No source PDFs available.
Inert-gas surge arrester for telecommunication and signalling equipment, designed to protect circuits from lightning, earth-return, and other transient overvoltages.
Pre-ionized inert-gas surge arrester for telecommunication and signalling systems, designed to provide reliable protection against lightning and earth-return overvoltages.
Pre-ionized inert-gas surge arrester for telecommunication and signalling systems, designed to provide reliable protection against lightning and earth-return overvoltages.
Inert-gas surge arrester family for protecting telecommunication and signalling systems against lightning, earth-return, and other transient overvoltages.
Pre-ionized inert-gas surge arrester with approximately 350 V nominal striking voltage, designed for transient-overvoltage protection in telecommunication and signalling systems.
Inert-gas surge arrester family for protecting telecommunication and signalling systems against lightning, earth-return, and other transient overvoltages.
No source PDFs available.
Inert-gas surge arrester designed specifically to protect coaxial-cable amplifiers from lightning, earth-return, and related transient overvoltages.
Inert-gas surge arrester designed specifically to protect coaxial-cable amplifiers from lightning, earth-return, and related transient overvoltages.
No source PDFs available.
Subminiature flying-lead surge arrester for protecting telecommunication and signalling installations against momentary low-energy surge voltages.
Subminiature flying-lead surge arrester with approximately 470 V nominal breakdown voltage, designed for momentary low-energy transient protection.
Subminiature flying-lead surge arrester designed for primary protection of 220 V AC apparatus against momentary low-energy surge voltages.
Inert-gas surge arrester with approximately 245 V nominal striking voltage, designed to protect telecommunication and signalling systems against lightning and earth-return overvoltages.
Inert-gas surge arrester family designed to protect telecommunication and signalling systems against lightning, earth-return, and related transient overvoltages.
No source PDFs available.
| Expand sections | More | Electrical Summary | General Summary | ||||
|---|---|---|---|---|---|---|---|
1960Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | RCA protective breakdown tube for AC circuits, conducting when voltage exceeds its threshold to protect associated equipment from excessive voltage. | ||||
1961Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | RCA protective breakdown tube for higher-voltage AC circuits, conducting at a defined threshold to protect associated equipment from excessive voltage. | ||||
1B25Specialized | Specialized - Switching TubeSurgeProtectorCold cathode |
| Gas-discharge protective tube that breaks down near 160 V to protect circuits against excessive voltage. | ||||
1B32Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | Refer to variations | Two-electrode gas-filled spark-gap protective tube with approximately 1 kV initial breakdown voltage, intended for overvoltage protection rather than commanded pulse switching. | ||||
4349Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold. | ||||
4369Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold. | ||||
4370Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold. | ||||
4371Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold. | ||||
4372Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold. | ||||
4373Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold. | ||||
4380Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold. | ||||
4381Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold. | ||||
4390Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold. | ||||
4397Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Gas-discharge surge arrester designed to protect lines and electronic apparatus against transient overvoltage by conducting when the applied voltage exceeds its protective threshold. | ||||
DRG362Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Neon-helium gas-filled telephone-line surge protector. Gas breakdown diverts damaging overvoltage transients away from communications equipment without requiring a heater. | ||||
TG14Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Bendix cold-cathode sealed spark gap for high-voltage overvoltage protection. Gas breakdown diverts damaging transients away from protected equipment. | ||||
TG20Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Bendix cold-cathode sealed spark gap for high-voltage overvoltage protection. Gas-discharge breakdown safely shunts damaging voltage surges. | ||||
UA1Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Rare-gas-filled low-voltage surge arrester for protecting low-current installations and cables against lightning, atmospheric overvoltages, and accidental contact with power lines. | ||||
UA12Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Inert-gas surge arrester designed to protect aerial lines and cables against lightning and atmospheric overvoltages by conducting when transient voltage exceeds its protective threshold. | ||||
UA12USpecialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Inert-gas surge arrester designed to protect aerial lines and cables against lightning and atmospheric overvoltages by conducting when transient voltage exceeds its protective threshold. | ||||
UA230Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Inert-gas surge arrester for telecommunication and signalling equipment, designed to protect circuits from lightning, earth-return, and other transient overvoltages. | ||||
UA245ASpecialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Pre-ionized inert-gas surge arrester for telecommunication and signalling systems, designed to provide reliable protection against lightning and earth-return overvoltages. | ||||
UA245BSpecialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Pre-ionized inert-gas surge arrester for telecommunication and signalling systems, designed to provide reliable protection against lightning and earth-return overvoltages. | ||||
UA350Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Inert-gas surge arrester family for protecting telecommunication and signalling systems against lightning, earth-return, and other transient overvoltages. | ||||
UA350BSpecialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Pre-ionized inert-gas surge arrester with approximately 350 V nominal striking voltage, designed for transient-overvoltage protection in telecommunication and signalling systems. | ||||
UA350USpecialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Inert-gas surge arrester family for protecting telecommunication and signalling systems against lightning, earth-return, and other transient overvoltages. | ||||
UA600Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Inert-gas surge arrester designed specifically to protect coaxial-cable amplifiers from lightning, earth-return, and related transient overvoltages. | ||||
UA600USpecialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Inert-gas surge arrester designed specifically to protect coaxial-cable amplifiers from lightning, earth-return, and related transient overvoltages. | ||||
UAM120Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Subminiature flying-lead surge arrester for protecting telecommunication and signalling installations against momentary low-energy surge voltages. | ||||
UAM470Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Subminiature flying-lead surge arrester with approximately 470 V nominal breakdown voltage, designed for momentary low-energy transient protection. | ||||
UAM600Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Subminiature flying-lead surge arrester designed for primary protection of 220 V AC apparatus against momentary low-energy surge voltages. | ||||
YS245Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Inert-gas surge arrester with approximately 245 V nominal striking voltage, designed to protect telecommunication and signalling systems against lightning and earth-return overvoltages. | ||||
YS350Specialized | Specialized - Switching TubeSurgeProtectorCold cathode | - | Inert-gas surge arrester family designed to protect telecommunication and signalling systems against lightning, earth-return, and related transient overvoltages. |