Skip to main content

Specialized - Switching Tube ·SparkGapPulseSwitch

ZR7518

Cold-cathode vacuum triggered spark gap for crowbar and energy-storage switching, capable of controlling extremely large stored-energy discharges at high voltage.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

Cold-cathode vacuum triggered spark gap for crowbar and energy-storage switching, capable of switching 75,000 joules at high voltage.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

SparkGapPulseSwitch

X-ray radiationInterelectrode capacitances
Max plate voltage
150000 V
Max cathode current
100000 A

Published ratings and characteristics promoted semantically from the approved source.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1950 General Electric Transmitting Types

Published operating points and test conditions from this source.

SECTION 1

SparkGapPulseSwitch

Other

  • Maximum Plate Voltage

    150000 V

  • Maximum Cathode Current

    100000 A

  • Operating Voltage Minimum

    2000 V

  • Operating Voltage Maximum

    150000 V

  • Hold-Off Voltage Minimum

    180000 V

    Indefinite time

  • Peak Pulse Current

    100000 A

  • Charge per Operation Maximum

    1 C

Characteristic

  • Switching Energy

    75000 J

  • Heater Required

    No