Data set 01
1968 General Electric Co
Published operating points and test conditions from this source.
SparkGapPulseSwitch
Other
Interelectrode Leakage Resistance
10000 Mohm
Main Gap Operating Voltage
300 to 45000 V
MainGap
Main Gap Hold-Off Voltage Indefinite Minimum
55000 V
MainGap
Main Gap Peak Current Unidirectional Pulse Maximum
50000 A
MainGap
Charge Conducted Through Gap Per Operation Maximum
0.7 C
MainGap
Discharge Rate Maximum
2 per_min
MainGap
Delay Time Maximum
0.1 us
MainGap;AppliedVoltage=45kV
Jitter Maximum
0.1 us
MainGap;AppliedVoltage=45kV
Trigger Peak Voltage Typical
5000 V
TriggerGap
Trigger Short-Circuit Current Typical
40 A
TriggerGap
Characteristic
Typical Trigger Firing Voltage Range
1000 to 3000 V
TriggerGap
ApplicationLimit
Permitted Trigger Short-Circuit Current
100 A
TriggerGap
Preferred Trigger Pulse Width Maximum
2 us
TriggerGap