Data set 01
1950 General Electric Transmitting Types
Published operating points and test conditions from this source.
Triode
Other
Heater Voltage
5 V
Heater Current
2.5 A
Characteristic
Service
Grid-pulsed Class C oscillator
L-band
Voltage - Triode (single) ·Triode
Heat-sink and forced-air-cooled triode with internal feedback for grid-pulsed L-band oscillator service.
Heat-sink and forced-air-cooled triode with internal feedback for grid-pulsed oscillator service in L-band.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Grid-pulsed Class-C maximum plate ratings promoted; pulse current, grid voltage, pulse width and duty factor preserved as parameters.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Heater Voltage
5 V
Heater Current
2.5 A
Service
Grid-pulsed Class C oscillator
L-band
Data set 02
Published operating points and test conditions from this source.
Cathode Heating Time Minimum
1 min
Maximum Anode Temperature
250 C
Maximum Ceramic Temperature
200 C
DC Plate Current Maximum During Pulse
2 A
ClassC;GridPulsed
DC Grid Voltage Maximum
-200 V
ClassC;GridPulsed
Pulse Width Maximum
10 us
ClassC;GridPulsed
Duty Factor Maximum
0.01
ClassC;GridPulsed
DC Plate Voltage
1750 V
GroundedGrid;ClassC;1090MHz;QuarterLambdaOutput
DC Plate Current During Pulse
1.25 A
GroundedGrid;ClassC;1090MHz;QuarterLambdaOutput
DC Grid Voltage
-80 V
GroundedGrid;ClassC;1090MHz;QuarterLambdaOutput
DC Grid Current During Pulse
750 mA
GroundedGrid;ClassC;1090MHz;QuarterLambdaOutput
Power Output During Pulse Useful
1000 W
GroundedGrid;ClassC;1090MHz;QuarterLambdaOutput
Pulse Width
0.5 us
GroundedGrid;ClassC;1090MHz;QuarterLambdaOutput
Duty Factor
0.01
GroundedGrid;ClassC;1090MHz;QuarterLambdaOutput
Input Capacitance
16 pF
Output Capacitance
4.3 pF