Data set 01
1950 General Electric Transmitting Types
Published operating points and test conditions from this source.
Triode
Other
Heater Current
2.4 A
Characteristic
Service
Grid-pulsed Class C amplifier
L-band
Power - Triode ·Triode
Heat-sink-cooled General Electric power triode for grid-pulsed Class C amplifier operation in the L-band, particularly navigational-aid applications. Specialized pulse ratings and multi-kilovolt operation support microwave transmitter service.
Heat-sink-cooled triode designed for grid-pulsed Class-C amplifier service in L-band, particularly navigational-aid applications.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Grid-pulsed Class-C maximum ratings promoted from the printed table; plate/grid pulse currents and pulse limits preserved as parameters.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Heater Current
2.4 A
Service
Grid-pulsed Class C amplifier
L-band
Data set 02
Published operating points and test conditions from this source.
Cathode Heating Time Minimum
1 min
Maximum Anode Temperature
250 C
Maximum Ceramic Temperature
200 C
DC Plate Current Maximum During Pulse
3 A
ClassC;GridPulsed
DC Grid Voltage Maximum
-200 V
ClassC;GridPulsed
Pulse Width Maximum
10 us
ClassC;GridPulsed
Duty Factor Maximum
0.01
ClassC;GridPulsed
DC Plate Voltage
2000 V
GroundedGrid;ClassC;1150MHz;TypicalOperation;1000WOutput
DC Plate Current During Pulse
1.1 A
GroundedGrid;ClassC;1150MHz;TypicalOperation;1000WOutput
DC Grid Voltage
-80 V
GroundedGrid;ClassC;1150MHz;TypicalOperation;1000WOutput
DC Grid Current During Pulse
350 mA
GroundedGrid;ClassC;1150MHz;TypicalOperation;1000WOutput
Power Output During Pulse
1000 W
GroundedGrid;ClassC;1150MHz;TypicalOperation;1000WOutput
Drive Power During Pulse
200 W
GroundedGrid;ClassC;1150MHz;TypicalOperation;1000WOutput
Pulse Width
10 us
GroundedGrid;ClassC;1150MHz;TypicalOperation;1000WOutput
Duty Factor
0.01
GroundedGrid;ClassC;1150MHz;TypicalOperation;1000WOutput
DC Plate Voltage
2000 V
GroundedGrid;ClassC;1150MHz;TypicalOperation;2000WOutput
DC Plate Current During Pulse
2.25 A
GroundedGrid;ClassC;1150MHz;TypicalOperation;2000WOutput
DC Grid Voltage
-80 V
GroundedGrid;ClassC;1150MHz;TypicalOperation;2000WOutput
DC Grid Current During Pulse
750 mA
GroundedGrid;ClassC;1150MHz;TypicalOperation;2000WOutput
Power Output During Pulse
2000 W
GroundedGrid;ClassC;1150MHz;TypicalOperation;2000WOutput
Drive Power During Pulse
350 W
GroundedGrid;ClassC;1150MHz;TypicalOperation;2000WOutput
Pulse Width
10 us
GroundedGrid;ClassC;1150MHz;TypicalOperation;2000WOutput
Duty Factor
0.004
GroundedGrid;ClassC;1150MHz;TypicalOperation;2000WOutput
Input Capacitance
16.5 pF
Output Capacitance
4 pF
Plate-Cathode Capacitance
0.1 pF