Heater Current . . . ... . ... e, 3.5 3.8
4 A
Heater Current . . . ... . ... e, 3.5 3.8 4.0 Amperes
DC Plate Voltage, During Pulse
6 kV
DC Plate Voltage, During Pulse............ 6.0 Kilovolts Grounded-Grid Service at 1300 Megacycles, 3% A Output Circuit
DC Plate Current, During Pulse
10 A
DC Plate Current, During Pulse.. 10.0 Amperes DC Plate Voltage, During Pulse........_. 6.0 Kilovolts
DC Grid Voltage, During Pulse...... .. —
400 V
DC Grid Voltage, During Pulse...... .. —400 Volts DC Plate Current, During Pulse......... 7.0 Amperes
DC Grid Current, During Pulse
5 A
DC Grid Current, During Pulse............. 5.0 Amperes DC Grid Current, During Pulse.....__..___ 4.3 Amperes
Plate Dissipation§
110 W
Plate Dissipation§ 110 Watts (Grid Resistor = 50 Ohms)
Pulse Width ¢
10 us
Pulse Width ¢ 10 Microseconds Power Output, During Pulse (Useful) 24.0 Kilowatts
Duty Factor¢ .. 0.001 Pulse Width
10 us
Duty Factor¢ .. 0.001 Pulse Width 10 Microseconds
DC Plate Voltage
2.6 kV
DC Plate Voltage 2.6 Kilovolts Grounded-Grid Circuit at 1100 Megacyles, 14 A Output
DC Plate Current, During Pulse
3 A
DC Plate Current, During Pulse 3.0 Amperes DC Plate Voltage 1750 1950 2200 Volts
DC Grid Voltage —
200 V
DC Grid Voltage —200 Volts DC Plate Current, During Pulse........_.. 2.6 2.7 Amperes
Plate Dissipation
110 W
Plate Dissipation 110 Watts DC Grid Voltage Supply**..._... - —97 —104 —104 Volts
Pulse Width¢
15 us
Pulse Width¢ 15 Microseconds DC Grid Current, During Pulse.............. 1.05 1.2 1.26 Amperes
Duty Factor¢ 0.02 Power Output, During Pulse (Useful) 1.5 2.0
2.4 kW
Duty Factor¢ 0.02 Power Output, During Pulse (Useful) 1.5 2.0 2.4 Kilowatts
Pulse Width 10 10
10 us
Pulse Width 10 10 10 Microseconds
1100 mcs, 2 kw, .02 duty condition, the typical heater voltage is
5.5 V
1100 mcs, 2 kw, .02 duty condition, the typical heater voltage is 5.5 volts.
** With a series grid resistance of
50 Ohm
** With a series grid resistance of 50 ohms.