Skip to main content

Power - Triode (over 1000V 100W) ·Triode

ZP1025

Forced-air-cooled metal-ceramic triode designed for pulsed L-band grounded-grid oscillator service.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
6.3 V / 3.5 A

Description

Metal-ceramic heat-sink and forced-air-cooled triode for pulsed L-band grounded-grid oscillator service.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
3.5 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Max plate voltage
6000 V
Max plate dissipation
110 W
Max cathode current
10 A

Promoted fields mapped semantically from printed ratings/characteristics headings; pulsed and microwave-specific limits remain in parameter rows when fixed-field semantics are ambiguous.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1950 General Electric Transmitting Types

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • HeaterOrFilamentVoltage

    6.3 V

  • HeaterOrFilamentCurrent

    3.8 A

  • CathodeToPlateCapacitance

    0.45 pF

Other

  • UsefulPowerOutputDuringPulse

    40 kW

    PulsedOscillator

  • UsefulPowerOutputDuringPulse

    2 kW

    1100MHz;DutyFactor=0.02

Data set 02

1968 General Electric Co

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Heater Current . . . ... . ... e, 3.5 3.8

    4 A

    Heater Current . . . ... . ... e, 3.5 3.8 4.0 Amperes

  • DC Plate Voltage, During Pulse

    6 kV

    DC Plate Voltage, During Pulse............ 6.0 Kilovolts Grounded-Grid Service at 1300 Megacycles, 3% A Output Circuit

  • DC Plate Current, During Pulse

    10 A

    DC Plate Current, During Pulse.. 10.0 Amperes DC Plate Voltage, During Pulse........_. 6.0 Kilovolts

  • DC Grid Voltage, During Pulse...... .. —

    400 V

    DC Grid Voltage, During Pulse...... .. —400 Volts DC Plate Current, During Pulse......... 7.0 Amperes

  • DC Grid Current, During Pulse

    5 A

    DC Grid Current, During Pulse............. 5.0 Amperes DC Grid Current, During Pulse.....__..___ 4.3 Amperes

  • Plate Dissipation§

    110 W

    Plate Dissipation§ 110 Watts (Grid Resistor = 50 Ohms)

  • Pulse Width ¢

    10 us

    Pulse Width ¢ 10 Microseconds Power Output, During Pulse (Useful) 24.0 Kilowatts

  • Duty Factor¢ .. 0.001 Pulse Width

    10 us

    Duty Factor¢ .. 0.001 Pulse Width 10 Microseconds

  • DC Plate Voltage

    2.6 kV

    DC Plate Voltage 2.6 Kilovolts Grounded-Grid Circuit at 1100 Megacyles, 14 A Output

  • DC Plate Current, During Pulse

    3 A

    DC Plate Current, During Pulse 3.0 Amperes DC Plate Voltage 1750 1950 2200 Volts

  • DC Grid Voltage —

    200 V

    DC Grid Voltage —200 Volts DC Plate Current, During Pulse........_.. 2.6 2.7 Amperes

  • Plate Dissipation

    110 W

    Plate Dissipation 110 Watts DC Grid Voltage Supply**..._... - —97 —104 —104 Volts

  • Pulse Width¢

    15 us

    Pulse Width¢ 15 Microseconds DC Grid Current, During Pulse.............. 1.05 1.2 1.26 Amperes

  • Duty Factor¢ 0.02 Power Output, During Pulse (Useful) 1.5 2.0

    2.4 kW

    Duty Factor¢ 0.02 Power Output, During Pulse (Useful) 1.5 2.0 2.4 Kilowatts

  • Pulse Width 10 10

    10 us

    Pulse Width 10 10 10 Microseconds

  • 1100 mcs, 2 kw, .02 duty condition, the typical heater voltage is

    5.5 V

    1100 mcs, 2 kw, .02 duty condition, the typical heater voltage is 5.5 volts.

  • ** With a series grid resistance of

    50 Ohm

    ** With a series grid resistance of 50 ohms.

Capacitance

  • Anode Temperature § . . . . . . . i i it i ittt e e e e e e e e e e e e

    250 C

    Anode Temperature § . . . . . . . i i it i ittt e e e e e e e e e e e e 250 C

  • Ceramic Temperature at Any Point, maximum

    200 C

    Ceramic Temperature at Any Point, maximum ...................... 200 C

Characteristic

  • Diameter A

    0.03 in

    Diameter A - 0,030 inches

  • Diameter B

    0.036 in

    Diameter B - 0,036 inches

  • Diameter C

    0.042 in

    Diameter C - 0,042 inches

  • ment terminal diameter (B)

    0.016 in

    ment terminal diameter (B) - 0.016 inches,