Data set 01
1973 Nixie Siemens
Published operating points and test conditions from this source.
Nixie
Characteristics
Ignition voltage
175 V
Maximum/typical threshold shown in source table
Extinction voltage
115 V
Source table value
Cathode current (source sp value)
14 mA
Pulse-supply table; source abbreviation 'sp'
Cathode current (source cr value)
2 mA
Pulse-supply table; source abbreviation 'cr'
Mean current (source sp value)
0.7 mA
Pulse-supply table; source abbreviation 'sp'
Mean current (source cr value)
0.1 mA
Pulse-supply table; source abbreviation 'cr'
Other
Maximum supply voltage
175 V
Absolute limit table
Cathode current limit (source sp value)
11 mA
Pulse-supply table; source abbreviation 'sp'
Cathode current limit (source cr value)
1 mA
Pulse-supply table; source abbreviation 'cr'
Mean cathode current limit (source sp value)
1.6 mA
Pulse-supply table; source abbreviation 'sp'
Mean cathode current limit (source cr value)
0.16 mA
Pulse-supply table; source abbreviation 'cr'
Peak cathode current limit (source sp value)
18 mA
Pulse-supply table; source abbreviation 'sp'
Peak cathode current limit (source cr value)
3 mA
Pulse-supply table; source abbreviation 'cr'
Envelope temperature minimum
-20 degC
Operating envelope temperature range
Envelope temperature maximum
70 degC
Operating envelope temperature range
Display characters
0 to 9 with left and right decimal points
Translated from French source
Display orientation
side
Viewing orientation
Character height
13.1 mm
Display geometry
Maximum tube height
30.5 mm
Mechanical dimension
Maximum tube width/diameter
13 mm
Mechanical dimension as printed
Supply mode
Pulse supply
Catalog column heading