Long-life cold-cathode ten-digit side-view numerical indicator with red contrast filter. Manufacturer documentation specifies its glow-discharge ignition and operating behavior and display geometry for direct decimal readout.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
19
Nominal heater
-

Description

Long-life cold-cathode ten-digit side-view Nixie indicator with red contrast filter. The datasheet specifies cold-cathode ignition/operating behavior and display geometry for numerical indication.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
19
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Nixie

X-ray radiationInterelectrode capacitances
Max cathode current
12 mA
Regulator starting voltage
170 V
Regulator maintaining voltage
115 V

Cold-cathode discharge/display section; explicit published limits and operating data are retained as section parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1969 Nixie Mullard

Published operating points and test conditions from this source.

SECTION 1

Nixie

Other

  • Numeral/Character Height

    15.5 mm

    Published mechanical/display data

  • Maximum Peak Cathode Current

    12 mA

    Published peak limit

Characteristic

  • Supply Voltage

    170 V

    Published operating data

  • Cathode Current

    2.5 mA

    Published average/normal value

Data set 02

196X Nixie Random Datasheets

Published operating points and test conditions from this source.

SECTION 1

Nixie

Other

  • Numeral height

    15.5 mm

  • Supply voltage minimum

    170 V

  • Distance between mounting centres minimum

    19 mm

  • Average cathode current maximum

    3.5 mA

    Each digit; repetition period max 10 ms

  • Peak cathode current maximum

    12 mA

    Each digit

  • Average cathode current minimum

    1.5 mA

    During any conduction period

  • Anode voltage necessary for ignition minimum

    170 V

  • Pulse duration minimum

    100 µs

  • Bulb temperature range

    -50 to 70 °C

  • Maximum dip-solder temperature

    240 °C

    At least 5 mm from seals

  • Maximum dip-solder duration

    10 s

    At 240 °C

Characteristics

  • Numerals

    1234567890

  • Cathode current recommended

    2.5 mA

  • Ignition voltage minimum

    170 V

    20-50 °C

  • Cathode current for coverage minimum

    1.5 mA

    Average during any conduction period

  • Extinguishing voltage

    115 V

  • Life expectancy minimum

    5000 h

    Continuous display of one numeral at 2.5 mA, room temperature

  • Life expectancy minimum

    30000 h

    Display changed to another numeral every 100 h or less; 2.5 mA, room temperature

Data set 03

1999 Philips E-Z

Published operating points and test conditions from this source.

SECTION 1

Nixie

Characteristic

  • Numeral height

    15.5 mm

    Numeral height 15.5 mm

  • Cathode current

    2.5 mA

    Cathode current Ik 2.5 mA

  • Ignition voltage

    170 V

    Ignition voltage Vign min. 170 'V

  • Ignition delay

    3

    Ignition delay see page 3

  • Maintaining voltage

    4

    Maintaining voltage see page 4

  • Extinguishing voltage

    115

    Extinguishing voltage Vext 115V

  • LIFE EXPECTANCY at [ = 2.5 mA and room temperature 1)

    1 mA

    LIFE EXPECTANCY at [ = 2.5 mA and room temperature 1)

  • Anode voltage necessary for ignition

    170

    Anode voltage necessary for ignition Va min. 170 Vv

  • Pulse duration

    100 us

    Pulse duration Timp min. 100 us

  • 1) For bulb temperatures below 0°C the life expectancy of the tube is substantially

    0 °C

    1) For bulb temperatures below 0°C the life expectancy of the tube is substantially

Other

  • Supply voltage

    170 V

    Supply voltage Vp, min. 170 V

  • temperature of 240°C for a maximum of 10 s.

    10 °C

    temperature of 240°C for a maximum of 10 s.

  • Cathode current, recommended

    2.5 mA

    Cathode current, recommended I 2.5 mA

  • Bulb temperature

    70

    Bulb temperature thylb ~ max. +70 ©°C

  • The graphson pages 8, 9 and 12 give the relationship between the anode supply volt-

    12

    The graphson pages 8, 9 and 12 give the relationship between the anode supply volt-