Skip to main content

Nixie ·Nixie

ZM1200

Valvo Pandicon gas-filled cold-cathode fourteen-decade numerical display. Each position provides digits 0–9 plus decimal and thousands marks, with common corresponding cathodes and separate anodes; designed for pulsed multiplexed operation and long service life.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
Dual special base
Socket code
-
Base pins
17
Nominal heater
-

Description

Valvo ZM1200 Pandicon is a gas-filled cold-cathode fourteen-decade numerical display. Each decade contains digits 0 through 9 plus decimal-point and thousands-separator marks, with common corresponding cathode connections and separate anodes for the fourteen positions. It is intended for pulsed multiplexed operation and long service life.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
Dual special base
Socket code
-
Base pins
17
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Dual special base - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Nixie

X-ray radiationInterelectrode capacitances
Regulator maximum current
1.5 A
Regulator starting voltage
170 V

Fourteen repeated decimal display decades are electrically similar; one representative section row is stored per identical-section compression rule. Nixie-specific data are in TUBE_SECTION_PARAMETER.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1969 Nixie Valvo

Published operating points and test conditions from this source.

SECTION 1

Nixie

Other

  • Peak supply voltage

    170 V

    Published operating data

  • Pulse duration

    50 to 500 us

    Allowed pulse range

  • Driven-to-undriven cathode voltage

    70 to 100 V

    Recommended

  • Undriven anode supply voltage

    85 to 115 V

    Recommended

  • Screen voltage

    70 to 100 V

    Absolute range

  • Decimal/thousands mark series resistor

    10 kOhm

    +/-10%

  • Minimum peak anode current at 50 us

    6 mA

    Per anode

  • Minimum peak anode current at 150 us

    5 mA

    Per anode

  • Minimum peak anode current at 1000 us

    4 mA

    Per anode

  • Maximum peak anode current

    12 mA

    Per anode

  • Maximum average anode current

    1.5 mA

    Per anode; integration >=1 s

  • Mark-only peak anode current

    0.5 to 2 mA

    Decimal/thousands mark without digit

  • Mark-only average anode current

    - to 0.25 mA

    Integration >=1 s

  • Maximum voltage between arbitrary electrodes

    120 V

    Except driven anode

  • Ambient temperature

    -50 to 70 degC

    Absolute range

Characteristics

  • Ignition voltage

    170 V

    Typical

  • First ignition delay

    0.5 s

    First ignition

  • Subsequent ignition delay

    10 us

    Subsequent ignitions

  • Typical accelerated-test life

    50000 to - h

    High peak current/high repetition/duty test

  • Number of display decades

    14 count

    Each decade has digits 0-9 plus decimal/thousands marks

  • Digit height

    10 mm

    Side-visible

Data set 02

196X Nixie Random Datasheets

Published operating points and test conditions from this source.

SECTION 1

Nixie

Other

  • Peak supply voltage

    170 V

    Published operating data

  • Pulse duration

    50 to 500 us

    Allowed pulse range

  • Driven-to-undriven cathode voltage

    70 to 100 V

    Recommended

  • Undriven anode supply voltage

    85 to 115 V

    Recommended

  • Screen voltage

    70 to 100 V

    Absolute range

  • Decimal/thousands mark series resistor

    10 kOhm

    +/-10%

  • Minimum peak anode current at 50 us

    6 mA

    Per anode

  • Minimum peak anode current at 150 us

    5 mA

    Per anode

  • Minimum peak anode current at 1000 us

    4 mA

    Per anode

  • Maximum peak anode current

    12 mA

    Per anode

  • Maximum average anode current

    1.5 mA

    Per anode; integration >=1 s

  • Mark-only peak anode current

    0.5 to 2 mA

    Decimal/thousands mark without digit

  • Mark-only average anode current

    - to 0.25 mA

    Integration >=1 s

  • Maximum voltage between arbitrary electrodes

    120 V

    Except driven anode

  • Ambient temperature

    -50 to 70 degC

    Absolute range

Characteristics

  • Ignition voltage

    170 V

    Typical

  • First ignition delay

    0.5 s

    First ignition

  • Subsequent ignition delay

    10 us

    Subsequent ignitions

  • Typical accelerated-test life

    50000 to - h

    High peak current/high repetition/duty test

  • Number of display decades

    14 count

    Each decade has digits 0-9 plus decimal/thousands marks

  • Digit height

    10 mm

    Side-visible

Data set 03

1999 Philips E-Z

Published operating points and test conditions from this source.

SECTION 1

Nixie

Characteristic

  • Numeral height

    10 mm

    Numeral height 10 mm|

  • Decade pitch

    10 mm

    Decade pitch 10 mm

  • Anode current, peak

    9 mA

    Anode current, peak Iap 9 mA

  • The tube contains 10 common numeral cathode rails, one common decimal point

    10

    The tube contains 10 common numeral cathode rails, one common decimal point

  • cathode rail, one common punctuation-mark cathode rail, a common screen and 14

    14 a

    cathode rail, one common punctuation-mark cathode rail, a common screen and 14

  • subsequent ignitions

    10 us

    subsequent ignitions Tq 10 us

  • Maintaining voltage

    5

    Maintaining voltage Vi see page 5

  • 2) The decimal point and/or punctuation mark cathode(s) may not be operated without

    2 s

    2) The decimal point and/or punctuation mark cathode(s) may not be operated without

  • Voltage between any pair of electrodes

    120

    Voltage between any pair of electrodes 120

  • 1y Bulb temperatures below 10 °C result in a reduced life expectancy and changes

    10 a

    1y Bulb temperatures below 10 °C result in a reduced life expectancy and changes

  • 1) The decimal point maintaining voltage Vmdp and the punctuation mark maintaining

    1

    1) The decimal point maintaining voltage Vmdp and the punctuation mark maintaining

  • voltage Vmpm include the voltage drop at the 10 k€2 series resistor.

    2

    voltage Vmpm include the voltage drop at the 10 k€2 series resistor.

  • 3) Vi min. pertains to the minimum operating temperature and assumes the deci~

    3

    3) Vi min. pertains to the minimum operating temperature and assumes the deci~

  • 4) The maintaining voltage can be considered as the sum of a constant voltage anda

    4 a

    4) The maintaining voltage can be considered as the sum of a constant voltage anda

  • and 6 mA), depending on pulse duration. (See "Characteristics and operating condi-

    6 mA

    and 6 mA), depending on pulse duration. (See "Characteristics and operating condi-

Other

  • Supply voltage, peak

    170 V

    Supply voltage, peak Vbap min. 170 V

  • Ignition voltage

    170 A

    Ignition voltage Vign max. 170 A%

  • Ignition delay, first ignition

    0.5 s

    Ignition delay, first ignition Tq typ. max. 0.5 s

  • Recommended pulse duration

    500 MS

    Recommended pulse duration Timp 150 to 500 MS

  • Cathode selecting voltage

    100 v

    Cathode selecting voltage Vik max. 100 v

  • Off" anode voltage

    115 v

    Off" anode voltage Vaoft max. 115 v

  • Recommended screen voltage

    10 V

    Recommended screen voltage Vg 10 V below Vg

  • Ambient temperature

    70

    Ambient temperature tamb max. +70 o¢C

  • 2) Vj;, max. pertains to the maximum operating temperature and assumes the deci~

    2

    2) Vj;, max. pertains to the maximum operating temperature and assumes the deci~

  • Supply Vpo=190 +10V

    10

    Supply Vpo=190 +10V