Data set 01
1973 Nixie Siemens
Published operating points and test conditions from this source.
Nixie
Characteristics
Ignition voltage
180 V
Maximum/typical threshold shown in source table
Operating glow voltage
145 V
Approximate service voltage
Extinction voltage
115 V
Source table value
Nominal cathode current
2.25 mA
Main symbol/digit
Other
Maximum supply voltage
180 V
Absolute limit table
Cathode current
1.5 to 3 mA
Main symbol/digit continuous range
Maximum peak cathode current
4 mA
Main symbol/digit
Envelope temperature minimum
-20 degC
Operating envelope temperature range
Envelope temperature maximum
70 degC
Operating envelope temperature range
Display characters
+, -, ~, ohm
Translated from French source
Display orientation
front
Viewing orientation
Character height
max 13 mm
Display geometry
Maximum tube height
24.5 mm
Mechanical dimension
Maximum tube width/diameter
20.0 x 27.5 mm
Mechanical dimension as printed