Skip to main content

Nixie ·Nixie

ZM1162

Gas-filled cold-cathode decimal indicator in a space-saving rectangular envelope, providing direct frontal display of digits 0–9. Valvo preliminary data specify approximately 170 V ignition, 140 V burning voltage, and 2.5 mA mean cathode current.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
Special 14-pin
Socket code
B14A
Base pins
14
Nominal heater
-

Description

Valvo ZM1162 is a gas-filled cold-cathode decimal indicator with a space-saving rectangular envelope and direct frontal glow display of digits 0 through 9. Preliminary data specify 170 V ignition, about 140 V burning voltage, and 2.5 mA mean cathode current.

Socket description

Large readout/Nixie 14-contact base, 44.5 mm pin circle

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
Special 14-pin
Socket code
B14A
Base pins
14
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Special 14-pin - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Nixie

X-ray radiationInterelectrode capacitances
Max cathode current
3 mA
Regulator minimum current
1.5 A
Regulator maximum current
3 A
Regulator starting voltage
170 V
Regulator maintaining voltage
140 V

Cold-cathode discharge/display section; explicit published limits and operating data are retained as section parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1969 Nixie Mullard

Published operating points and test conditions from this source.

SECTION 1

Nixie

Other

  • Numeral/Character Height

    15.5 mm

    Published mechanical/display data

Characteristic

  • Supply Voltage

    170 V

    Published operating data

  • Minimum Ignition Voltage

    170 V

    Minimum anode-to-cathode voltage necessary for ignition

  • Cathode Current

    2.5 mA

    Published average/normal value

Data set 02

1969 Nixie Valvo

Published operating points and test conditions from this source.

SECTION 1

Nixie

Characteristics

  • Ignition voltage

    170 V

    Preliminary data

  • Burning voltage

    140 V

    Typical

  • Extinction voltage

    115 V

    Typical

  • Life with one digit continuously displayed

    5000 to - h

    Recommended conditions

  • Life with changing display

    30000 to - h

    Digit changed every 100 h or more often

  • Viewing angle

    90 deg

    Frontal display

  • Digit set

    0-9

    Direct frontal display

Other

  • Mean cathode current

    2.5 mA

    Recommended

  • Cathode current

    1.5 to 3 mA

    Absolute range

  • Peak cathode current

    - to 4 mA

    Pulse

  • Envelope temperature

    - to 70 degC

    Absolute maximum

Data set 03

196X Nixie Random Datasheets

Published operating points and test conditions from this source.

SECTION 1

Nixie

Characteristics

  • Ignition voltage

    170 V

    Preliminary data

  • Burning voltage

    140 V

    Typical

  • Extinction voltage

    115 V

    Typical

  • Life with one digit continuously displayed

    5000 to - h

    Recommended conditions

  • Life with changing display

    30000 to - h

    Digit changed every 100 h or more often

  • Viewing angle

    90 deg

    Frontal display

  • Digit set

    0-9

    Direct frontal display

Other

  • Mean cathode current

    2.5 mA

    Recommended

  • Cathode current

    1.5 to 3 mA

    Absolute range

  • Peak cathode current

    - to 4 mA

    Pulse

  • Envelope temperature

    - to 70 degC

    Absolute maximum

Data set 04

1999 Philips E-Z

Published operating points and test conditions from this source.

SECTION 1

Nixie

Characteristic

  • Numeral height

    15.5 mm

    Numeral height 15,5 mm

  • Cathode current

    2.5 mA

    Cathode current Iy 2.5 mA

  • Ignition voltage

    170

    Ignition voltage Vign min. 170

  • Ignition delay

    3

    Ignition delay see page 3

  • Extinguishing voltage

    118

    Extinguishing voltage Vext 118

  • LIFE EXPECTANCY at I) = 2,5 mA and room temperature 1)

    1 mA

    LIFE EXPECTANCY at I) = 2,5 mA and room temperature 1)

  • Anode voltage necessary for ignition

    170

    Anode voltage necessary for ignition Va min, 170

  • 1) For bulb temperatures below+100C the life expectancy of the tube is substan-

    100

    1) For bulb temperatures below+100C the life expectancy of the tube is substan-

  • age and the required anode load resistor for fixed values 0f Vi (voltage difference

    0

    age and the required anode load resistor for fixed values 0f Vi (voltage difference

Other

  • Supply voltage

    170 V

    Supply voltage Vba min, 170 V

  • Cathode current, recommended

    2.5 mA

    Cathode current, recommended Ig 2.5 mA

  • Bulb temperature

    70 oc

    Bulb temperature thulb max. +70 oc

  • The graphs on pages 7 to 9 give the relationship between the d.c. anode supply volt-

    9

    The graphs on pages 7 to 9 give the relationship between the d.c. anode supply volt-