Data set 01
1971 Nixie RFT
Published operating points and test conditions from this source.
Nixie
Other
Comparable RFT Type
Z5730M
Catalog cross-reference; comparable types are not guaranteed identical; ComparableRFT=Z5730M
Minimum Operating Supply Voltage
170 V
Published for comparable RFT type Z5730M; ComparableRFT=Z5730M
Cathode Current Minimum
1.5 mA
Published for comparable RFT type Z5730M; ComparableRFT=Z5730M
Cathode Current Maximum
2.5 mA
Published for comparable RFT type Z5730M; ComparableRFT=Z5730M
Peak Cathode Current
12 mA
Published for comparable RFT type Z5730M; ComparableRFT=Z5730M
Ambient Temperature Minimum
-50 °C
Published for comparable RFT type Z5730M; ComparableRFT=Z5730M
Ambient Temperature Maximum
70 °C
Published for comparable RFT type Z5730M; ComparableRFT=Z5730M
Displayed Symbols
0 to 9; decimal point right; +
Published for comparable RFT type Z5730M; ComparableRFT=Z5730M
Reading Direction
side
Published for comparable RFT type Z5730M; ComparableRFT=Z5730M
Symbol Height
13 mm
Published for comparable RFT type Z5730M; ComparableRFT=Z5730M
Maximum Viewing Distance
8 m
Published for comparable RFT type Z5730M; ComparableRFT=Z5730M
Mounting Orientation
Wire 7 facing front
Published for comparable RFT type Z5730M; ComparableRFT=Z5730M
Maximum Bulb Height
47.6 mm
Published for comparable RFT type Z5730M; ComparableRFT=Z5730M
Maximum Bulb Diameter
19 mm
Published for comparable RFT type Z5730M; ComparableRFT=Z5730M
Characteristic
Anode Striking Voltage
150 V
Published for comparable RFT type Z5730M; ComparableRFT=Z5730M
Anode Maintaining Voltage
140 V
Published for comparable RFT type Z5730M; ComparableRFT=Z5730M
Anode Extinction Voltage
120 V
Published for comparable RFT type Z5730M; ComparableRFT=Z5730M