Data set 01
1966 Nixie Telefunken
Published operating points and test conditions from this source.
Nixie
Characteristics
Ignition voltage
- to 170 V
Measured/operating data; maximum stated
Burning voltage
145 V
At cathode current 1 mA
Expected life
30000 h
Changing display at about 1 mA per digit; ambient temperature down to about -10 degC
Digit height
7.8 mm
Visible digit height
Maximum weight
5 g
Mechanical data
Other
Cathode current
0.7 to 1.4 mA
Measured and operating range
Minimum supply voltage
170 V
Absolute minimum supply requirement
Pulse cathode current
- to 1.5 mA
Maximum; pulse duration <=20 ms
Envelope temperature
-50 to 70 degC
Absolute range
Cathode-to-cathode bias voltage
40 to 120 V
For non-burning cathodes when required
Recommended off-cathode bias
80 V
Recommended when non-burning cathodes require positive bias
Recommended cathode current
1 mA
Approximate per displayed digit