Data set 01
1966 Nixie Telefunken
Published operating points and test conditions from this source.
Nixie
Characteristics
Ignition voltage
- to 170 V
Measured/general data; maximum stated
Burning voltage
143 V
Typical; at cathode current 2 mA
Burning current
1.5 to 3 mA
Specified operating range
Differential internal resistance
7.2 kOhm
Typical
Life with one digit continuously displayed
5000 to - h
At cathode current 2 mA
Life with changing display
50000 to - h
Changing indication; recommended bias 60 V
Other
Minimum supply voltage
170 V
Absolute minimum supply requirement
Pulse cathode current
- to 3.5 mA
Maximum; pulse duration <=20 ms
Cathode-to-cathode bias voltage
40 to 120 V
For non-burning cathodes when required
Envelope temperature
-50 to 70 degC
Absolute range
Recommended off-cathode bias
60 V
DC operation with bias
Ballast resistance
11 kOhm
DC operation; supply voltage 170 V; burning voltage about 145 V
Ballast resistance
24 kOhm
DC operation; supply voltage 200 V; burning voltage about 145 V
Ballast resistance
47 kOhm
DC operation; supply voltage 250 V; burning voltage about 145 V
Ballast resistance
68 kOhm
DC operation; supply voltage 300 V; burning voltage about 145 V
Ballast resistance
91 kOhm
DC operation; supply voltage 350 V; burning voltage about 145 V
Operating burning voltage
145 V
DC operation across specified supply-voltage examples