Data set 01
1965 Nixie Valvo
Published operating points and test conditions from this source.
Nixie
Characteristics
Ignition voltage
170 V
Typical characteristic
Extinction voltage
118 V
Typical characteristic
Life with one digit continuously displayed
5000 h
Recommended conditions
Other
DC supply voltage
200 V
Biased DC operation
DC cathode current
2 mA
Biased DC operation
DC burning voltage
140 V
Biased DC operation
Recommended off-cathode bias
60 V
Biased DC operation
Continuous cathode current
1.5 to 2.5 mA
Absolute range
Envelope temperature
-55 to 70 degC
Absolute range
Pulse cathode current
10 mA
Typical pulse operation
Pulse burning voltage
185 V
Typical pulse operation
Pulse duration
0.1 ms
Typical pulse operation
Pulse frequency
1000 Hz
Typical pulse operation
Maximum pulse cathode current
- to 12 mA
Absolute maximum
Pulse duration limits
0.1 to 2 ms
Absolute range