Skip to main content

Specialized - Switching Tube ·CounterSelectorSwitch

ZM1070

Cold-cathode decade counting, display, and switching tube supporting bidirectional counting. Sequential gas-discharge transfer provides electronic counting and visible indication.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
Special 13-pin
Socket code
B13B
Base pins
13
Nominal heater
-

Description

Valvo ZM1070/8433 is a gas-filled cold-cathode decade counting and display tube for forward and reverse counting. Ten separately brought-out cathodes provide a glow indication of the active count position.

Socket description

B13B Nixie 13-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
Special 13-pin
Socket code
B13B
Base pins
13
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Special 13-pin - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

CounterSelectorSwitch

X-ray radiationInterelectrode capacitances
Regulator minimum current
250 mA
Regulator maximum current
525 mA
Regulator maintaining voltage
195 V

Single indicator/counting section. Nixie-specific electrical ratings and operating data are retained in TUBE_SECTION_PARAMETER.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1965 Nixie Valvo

Published operating points and test conditions from this source.

SECTION 1

CounterSelectorSwitch

Characteristics

  • Maximum counting frequency

    5 kHz

    At 25 C

  • Minimum pulse spacing

    200 us

    At 25 C

  • Minimum discharge duration

    60 us

    Any counting cathode

  • Counting signal voltage

    -45 V

    For kA/kB

  • Reset voltage

    -225 to -120 V

    Published range

  • Burning voltage

    195 V

    At 475 V supply and 820 kOhm anode resistor

Other

  • Anode supply voltage

    375 to 550 V

    Absolute range

  • Supply time constant

    1 to - ms

    Minimum

  • Counting-cathode bias

    35 to 60 V

    For kA/kB

  • Voltage between counting cathodes

    - to 140 V

    Absolute maximum except reset

  • Maximum negative bias on any output cathode

    - to 20 V

    Absolute maximum

  • Average cathode current

    0.25 to 0.525 mA

    Absolute range

  • Ambient temperature

    - to 50 degC

    Absolute maximum

  • Recommended anode supply voltage

    475 V

    Typical circuit

  • Recommended anode resistor

    820 kOhm

    Typical circuit

  • Recommended anode current

    0.34 mA

    Typical circuit

  • Counting pulse amplitude

    -100 V

    Typical circuit

  • Counting pulse duration

    75 us

    Typical circuit

  • Counting cathode bias

    40 V

    kA/kB

  • Output pulse amplitude

    23 to 35 V

    Typical circuit

Data set 02

196X Nixie Random Datasheets

Published operating points and test conditions from this source.

SECTION 1

CounterSelectorSwitch

Characteristics

  • Maximum counting frequency

    5 kHz

    At 25 C

  • Minimum pulse spacing

    200 us

    At 25 C

  • Minimum discharge duration

    60 us

    Any counting cathode

  • Counting signal voltage

    -45 V

    For kA/kB

  • Reset voltage

    -225 to -120 V

    Published range

  • Burning voltage

    195 V

    At 475 V supply and 820 kOhm anode resistor

Other

  • Anode supply voltage

    375 to 550 V

    Absolute range

  • Supply time constant

    1 to - ms

    Minimum

  • Counting-cathode bias

    35 to 60 V

    For kA/kB

  • Voltage between counting cathodes

    - to 140 V

    Absolute maximum except reset

  • Maximum negative bias on any output cathode

    - to 20 V

    Absolute maximum

  • Average cathode current

    0.25 to 0.525 mA

    Absolute range

  • Ambient temperature

    - to 50 degC

    Absolute maximum

  • Recommended anode supply voltage

    475 V

    Typical circuit

  • Recommended anode resistor

    820 kOhm

    Typical circuit

  • Recommended anode current

    0.34 mA

    Typical circuit

  • Counting pulse amplitude

    -100 V

    Typical circuit

  • Counting pulse duration

    75 us

    Typical circuit

  • Counting cathode bias

    40 V

    kA/kB

  • Output pulse amplitude

    23 to 35 V

    Typical circuit