Data set 01
1965 Nixie Valvo
Published operating points and test conditions from this source.
CounterSelectorSwitch
Characteristics
Maximum counting frequency
5 kHz
At 25 C
Minimum pulse spacing
200 us
At 25 C
Minimum discharge duration
60 us
Any counting cathode
Counting signal voltage
-45 V
For kA/kB
Reset voltage
-225 to -120 V
Published range
Burning voltage
195 V
At 475 V supply and 820 kOhm anode resistor
Other
Anode supply voltage
375 to 550 V
Absolute range
Supply time constant
1 to - ms
Minimum
Counting-cathode bias
35 to 60 V
For kA/kB
Voltage between counting cathodes
- to 140 V
Absolute maximum except reset
Maximum negative bias on any output cathode
- to 20 V
Absolute maximum
Average cathode current
0.25 to 0.525 mA
Absolute range
Ambient temperature
- to 50 degC
Absolute maximum
Recommended anode supply voltage
475 V
Typical circuit
Recommended anode resistor
820 kOhm
Typical circuit
Recommended anode current
0.34 mA
Typical circuit
Counting pulse amplitude
-100 V
Typical circuit
Counting pulse duration
75 us
Typical circuit
Counting cathode bias
40 V
kA/kB
Output pulse amplitude
23 to 35 V
Typical circuit