Data set 01
1965 Nixie Valvo
Published operating points and test conditions from this source.
CounterSelectorSwitch
Characteristics
Maximum counting frequency
50 kHz
At 25 C
Minimum pulse spacing
20 us
At 25 C
Minimum discharge duration
6 us
Any counting cathode
Counting signal voltage
-85 V
For kA/kB; OCR sign preserved from source
Reset voltage
-140 to -100 V
Published range
Burning voltage
260 V
240-275 V at 0.8 mA
Other
Anode supply voltage
400 to 1000 V
Absolute range
Supply time constant
2 to - ms
Minimum
Voltage between counting cathodes
- to 140 V
Absolute maximum except reset
Counting-cathode bias relative to conducting cathode
40 to 60 V
Absolute range
Average cathode current
0.6 to 1 mA
Absolute range
Ambient temperature
- to 50 degC
Absolute maximum
Recommended anode supply voltage
525 V
Typical circuit
Recommended anode resistor
330 kOhm
Typical circuit
Recommended anode current
0.8 mA
Typical circuit
Counting pulse amplitude
-100 V
Typical circuit
Counting pulse duration
6 to - us
Minimum
Output pulse amplitude
12 to 24 V
Typical circuit